User Manual Part 2

Link CX-24 User’s Manual
Version 1.0 Page 70 February 2004
STATUS mandatory
DESCRIPTION
"Total number of enterprise traps sent since last reboot."
::= { link_cx_trap 1 }
link_cx_unit OBJECT IDENTIFIER ::= { link_cx 101 }
alarmTrap TRAP-TYPE
ENTERPRISE link_cx_unit
VARIABLES { rfPowerOutputLevel,
rfRssiLevel,
bitErrorRate,
losAlarmStatus,
txSynthLockAlarmStatus,
rxSynthLockAlarmStatus,
lowTxPowerAlarmStatus,
demodLockAlarmStatus,
lowRssiLevelAlarmStatus,
receiverOverloadAlarmStatus,
bitErrorRateAlarmStatus,
trapSentCounter }
DESCRIPTION
"A trap that indicates a change in one or more of the alarm conditions."
::= 1
configurationChangeTrap TRAP-TYPE
ENTERPRISE link_cx_unit
VARIABLES { rfTxAttenuateControl,
rfAtpcControl,
rfTxPowerLimit,
rfAtpcAddress,
rfChannel,
rfRssiAlarmThresholdSetting,
losAlarmControl,
trapSentCounter }
DESCRIPTION
"A trap that indicates a configuration change."
::= 2
unitTestTrap TRAP-TYPE
ENTERPRISE link_cx_unit
VARIABLES { rfTxAttenuateTimer,
localLoopbackControl,
rfLocalLoopbackTimer,
remoteLoopbackControl,
berTestControl,
pseudoAisControl,
trapSentCounter }
DESCRIPTION
"A trap that indicates the beginning or end of a test procedure.
An alarmTrap trap might result from this procedure."
::= 3
END