User Manual Part 2

Link CX-24 User’s Manual
Version 1.0 Page 68 February 2004
"The DS3/E3 local loopback control. When enabled, DS3/E3 data on the
local interface is looped back through the local interface.
When disabled, DS3/E3 data on the local interface is sent over
the radio link to the remote unit."
::= { link_cx_test 2 }
rfLocalLoopbackTimer OBJECT-TYPE
SYNTAX INTEGER (0..1800)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this value is greater than zero, the radio is in the local
loopback mode. The RF transmit signal on the local unit is
converted to the receive frequency of the local unit so it can
be received by the local unit, for the chosen period of time in
seconds. When this timer counts down to 0 the unit reverts to
normal operation in which the RF transmit signal on the local unit
is transmitted over the radio link to the remote unit. The duration
is selectable in 1 second intervals from 0 seconds to a maximum of
1800 seconds."
::= { link_cx_test 3 }
remoteLoopbackControl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DS3/E3 remote loopback control. With either setting of this
control, DS3/E3 data on the local interface is sent to the peer radio
and DS3/E3 data received from the peer radio goes to the local
interface. When enabled, the peer radio loops the data back to the
originating radio. When disabled, DS3/E3 data flow from end to end."
::= { link_cx_test 4 }
berTestControl OBJECT-TYPE
SYNTAX INTEGER {
alternatingOnesZeros(1),
allOnes(2),
allZeros(3),
disabled(4),
pseudorandom(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BER test mode control. The BER test is enabled by selecting one of
four different data patterns. The patterns are:
(1) alternating 1's and 0's, (2) all 1's, (3) all 0's, and
(5) pseudorandom 1's and 0's. The BER test is disabled by setting
the BER test control to 4."
::= { link_cx_test 5 }