User's Manual

15
APPENDIX B (Continued)
Table B - Authorized Cables with Minimum Lengths
Cable Type
Minimum Length
Maximum
Recommended
Lengths
RG58/U
LMR195
25 feet
40 feet
LMR200
30 feet
50 feet
LMR240
40 feet
65 feet
LMR400
75 feet
100 feet
LMR500
90 feet
150 feet
LMR600
120 feet
175 feet
LMR900
150 feet
275 feet
LMR1200
200 feet
375 feet
LMR1700
300 feet
500 feet
NOTE: This table is for reference only. In order to comply with FCC Part 15 Certification,
the installer must insure that actual coax cable used between the radio and the
Converter/Amplifier has at least 5 dB of insertion loss.
CAUTION: The transmit input power to the remote mounted converter must be limited to 10