Specifications

8.5
(0.34)
8.5
(0.34)
2
M
4
4
M
4
9
< Model Designation < Capacity Code Designation
Voltage
Class
Capacity
kW (HP)
0.1 (0.13)
0.2 (0.25)
0.4 (0.5)
0.75 (1)
1.5 (2)
2.2 (3)
3.7 (5)
0.1 (0.13)
0.2 (0.25)
0.4 (0.5)
0.75 (1)
1.5 (2)
0.37 (0.5)
0.55 (0.75)
1.1 (1.5)
1.5 (2)
2.2 (3)
3.0 (4)
3.7 (5)
Fig.
No.
1
68
(2.68)
68
(2.68)
108
(4.25)
140(5.51) 128(5.04) 161(6.34) 128(5.04) 118(4.65) 5 (0.20)
2.1(4.63) 96.7 52.4
128
(5.04)
128
(5.04)
128
(5.04)
70
(2.76)
102 (4.16)
56
(2.20)
56
(2.20)
96
(3.78)
118
(4.65)
118
(4.65)
118
(4.65)
5
(0.20)
5
(0.20)
5
(0.20)
1
2
2
2
68
(2.68)
108
(4.25)
108
(4.25)
140
(5.51)
128
(5.04)
128
(5.04)
128
(5.04)
128
(5.04)
70
(2.76)
154
(6.06)
161
(6.34)
129 (5.08)
122 (4.80)
154 (6.06)
81 (3.19)
99 (3.90)
129 (5.08)
56
(2.20)
96
(3.78)
96
(3.78)
128
(5.04)
118
(4.65)
118
(4.65)
118
(4.65)
118
(4.65)
5
(0.20)
5
(0.20)
5
(0.20)
5
(0.20)
0.5 (1.1)
0.5 (1.1)
0.8 (1.76)
0.9 (1.98)
1.3 (2.83)
1.5 (3.31)
3.7
7.7
15.8
28.4
53.7
60.4
3.7
7.7
15.8
28.4
53.7
9.4
15.1
30.3
45.8
50.5
58.2
73.4
10.4
12.3
16.1
23.0
29.1
13.7
15.0
24.6
29.9
32.5
37.6
44.5
14.1
20.1
31.9
51.4
82.8
23.1
30.1
54.9
75.7
83.0
95.8
117.9
9.3
10.3
12.3
16.7
19.1
34.4
13.0
18.0
28.1
45.1
72.8
94.8
149.1
0.9 (1.98)
1.5 (3.31)
1.0 (2.20)
1.1 (2.43)
1.5 (3.31)
2.1 (4.63)
Mass
kg (lb)
W H D W1 H1 H2 Fin
Inside
Unit
Total Heat
Loss
Dimensions in mm (inches) Heat Loss W
200V
Three-phase
200V
Single-phase
400V
Three-phase
112 (4.41)
129 (5.08)
154 (6.06)
No.
Applicable maximum motor output
0P1 0.1kW (0.13HP)
0P2 0.2kW (0.25HP)
0P4 0.4kW (0.5HP)
0P7 0.75kW (1HP)
1P5 1.5kW (2HP)
2P2 2.2kW (3HP)
3P0 3.0kW (4HP)
3P7 3.7kW (5HP)
0.1kW (0.13HP)
0.2kW (0.25HP)
0.4kW (0.5HP)
0.75kW (1HP)
1.5kW (2HP)
2.2kW (3HP)
3.0kW (4HP)
3.7kW (5HP)
No.
Applicable maximum motor output
0P1
0P2
0P4
0P7
1P5
2P2
3P0
3P7
No. Voltage Class
B Single-phase 200VAC
2 Three-phase 200VAC
4 Three-phase 400VAC
No. Type
No. Specifications
A Japan domestic standards
Conformed to UL/cUL, CE marking.
Inverter
VS mini J7 series
A
With digital operator (with volume)
B Without digital operator
C
With digital operator (without volume)
B Single-phase 200VAC
No. Phase / Voltage
2 Three-phase 200VAC
4 Three-phase 400VAC
CIMR J7AA20P1
No. Protective structure
0 Open chassis (IP20)
20P10
< Models
Voltage
class
Single-phase
200V
With Digital
Operator
With Digital
Operator
With Digital
Operator
Without Digital Operator
With Analog Volume
Without Analog Volume
With Analog Volume
Without Analog Volume
With Analog Volume
Without Analog Volume
Without Digital Operator
Without Digital Operator
Note: Models without cooling fin are available.
Contact your YASKAWA representative.
>: provided
Three-phase
200V
Three-phase
400V
Description
0P1
(0.1)
0P2
(0.2)
0P4
(0.4)
0P7
(0.7)
1P5
(1.5)
2P2
(2.2)
3P0
(3.0)
3P7
(3.7)
>>>>>
>>>>>
>>>>>>>
>>>>>>>
>>>>>>>
>>>>>>>
Model
CIMR-J7A=B
CIMR-J7C=B
CIMR-J7B=B
CIMR-J7A=2
CIMR-J7C=2
CIMR-J7B=2
CIMR-J7A=4
CIMR-J7C=4
CIMR-J7B=4
Capacity code to be filled in model (Max. applicable motor output kW)
Figure 1 Figure 2