Specifications

Major Features of the VS mini J7
Power supply high-harmonics suppressed
An optional DC reactor can be connected, and of
course AC reactors are also available.
300
(%)
(min
-
1
)
200
100
100 1,000 2,000
0
SPEED
TORQUE
Outstanding starting torque characteristics
Motor: 200V, 0.4kW, 4-pole
105%1.5Hz
155% 3Hz
4
Full-range automatic torque boost
Delivers outsanding starting torque (150%/3Hz) for its
class, for smooth machinery start-up.
Full range of protective functions
High-speed current-limiting function minimizes over-
current trips (above 250% of rated current) for enhanced
tripless operation (restart after momentary power loss,
stall prevention function, fault retry, etc.)
Inrush current suppression circuit buit-in.
Diverse operating methods and functions
Multi-step speed operation (up to nine steps),
UP/DOWN operation and jog operation.
Full range of functions, including slip compensation,
overtorque detection and high-speed search.
Just wire it up and run!
Frequency volume setting knob located on the control
panel (operator) as a standard feature. Immediate
operation after you supply power.
If remote operation is required, the optional operator
and cable can be mounted on your control panel.
Simple installation and wiring
The main circuit terminals are arranged in upper and
lower rows, so you can wire it up just like a contactor.
Main and control circuit terminals are screw-type, for
simple wiring and improved reliability.
One-touch mounting/detaching with DIN rail attach-
ments.
Wide range of input/output
Multi-function I/O terminals, 0-10V, 4-20mA or 0-20mA
inputs, as well as analog monitors are available.
Application freedom is increased since multi-function
inputs can be set to PNP or NPN.
One-touch mounting and/
or detaching. The life of the
cooling fan is extended by a
cooling fan ON/OFF control.
Performance
and
Functions
Operability
Screw-type
terminals
Removable
cooling fan
10Hz
3Hz
6Hz 30Hz
60Hz
1.5Hz
Even for a single given machine, the required motor torque will
vary with the load conditions. The full-range automatic torque
boost function automatically adjusts V (voltage) in V/f as
required. The VS mini J7 can adjust V for the required torque
during acceleration as well as during constant-speed operation.
The inverter calculates the required torque automatically.
Supprot for RS-232C and RS-485/422 (MEMOBUS protocol)
available as options.
Simple maintenance