YASKAWA COMPACT INVERTER FOR GENERAL-USE VS mini J7 TIFIE D EM ER A GE ST MAN Certified for ISO9001 and ISO14001 C 200V CLASS (THREE-PHASE) 0.1 TO 3.7kW (0.13 TO 5HP) 200V CLASS (SINGLE-PHASE) 0.1 TO 1.5kW (0.13 TO 2HP) 400V CLASS (THREE-PHASE) 0.2 TO 3.7kW (0.25 TO 5HP) Y MENT S QUALITY SYSTEM JQA-0403 JQA-EM0498 LITERATURE NO.
Inverter Magic Instant Upgrade for Your Small Machinery! The VS mini J7 inverter delivers the solution for all those users who want to easily upgrade small machinery to variable-speed drives. Turn your machinery into the optimum drive through our powerful performance and rich array of functions. Try the compact, economical VS mini J7 for simple operation and maintenance. Only 128mm Tall Compact design means it fits into your panel efficiently.
Major Features of the VS mini J7 Performance and Functions Operability Full-range automatic torque boost Simple installation and wiring ●Delivers outsanding starting torque (150%/3Hz) for its class, for smooth machinery start-up. ●The main circuit terminals are arranged in upper and lower rows, so you can wire it up just like a contactor. Outstanding starting torque characteristics ●Main and control circuit terminals are screw-type, for simple wiring and improved reliability. 105%/1.
Compact Size 128 (5.04) Efficient layout in panel design means smaller volume requirements, and because dimensions are uniform for all 128mm-height (5.04 inches) models, your panel layout is simplified, too. 128 (5.04) ●Compact Dimensions in mm (inches) 78.5 (3.09) 137.5 (5.41) 68 (2.68) 108 (4.25) (Example of 200V, three–phase, 0.1kW model) (Example of 200V, three–phase, 1.5kW model) 200V 3-phase 0.1 to 0.75kW Single-phase 0.1 to 0.4kW 200V 3-phase 1.5 to 3.7kW Single-phase 0.75 to 1.
OPERATING DIGITAL OPERATOR Display and Keypad Description Digital Operator Function Display LEDs Selected function is lit (See the functions below). Its data is displayed on data display. Data Display Operation Key Display Selection Key Press to run the motor. The RUN light is ON while running. Switch functions among function display LEDs. Alarm LED Enter Key Enter data when setting constants. After selecting constant No. at PRGM mode, data are displayed.
Switching the Function LEDs Changing the Constant Data 6 0. 0 Power ON FREF Changing the displayed data • Example: Changing frequency reference from 60Hz to 30Hz Frequency reference setting/monitor (Hz) DSPL FOUT 3 0. 0 F R EF F R EF < 6 0. 0 6 0. 0 Frequency reference: 60Hz Output frequency monitor (Hz) 3 0. 0 FR E F ENTER The data blinks while changing The data is entered. DSPL 0 0.
STANDARD SPECIFICATIONS Voltage Class Model CIMR-J7A=???? 200V single-/ three-phase Three20P1 phase 1 * SingleB0P1 phase Control Characteristics Power Supply Output Characteristics Max. Applicable Motor Output*2 kW (HP) Inverter Capacity kVA Rated Output Current A Max. Output Voltage V 20P4 20P7 21P5 400V three-phase 22P2 23P7 40P2 40P4 40P7 41P5 42P2 43P0 B0P2 B0P4 B0P7 B1P5 — — — — — — — — — 0.2 (0.25) 0.4 (0.5) 0.75 (1) 1.5 (2) 2.2 (3) 3.7 (5) 0.37 (0.5) 0.55 (0.
4–M4 2–M4 8.5 (0.34) 8.5 (0.34) Figure 1 Voltage Class Capacity kW (HP) 200V Three-phase 200V Single-phase 400V Three-phase 0.1 (0.13) 0.2 (0.25) 0.4 (0.5) 0.75 (1) 1.5 (2) 2.2 (3) 3.7 (5) 0.1 (0.13) 0.2 (0.25) 0.4 (0.5) 0.75 (1) 1.5 (2) 0.37 (0.5) 0.55 (0.75) 1.1 (1.5) 1.5 (2) 2.2 (3) 3.0 (4) 3.7 (5) Fig. No. 1 2 Figure 2 Dimensions in mm (inches) W H 68 (2.68) 68 (2.68) 108 (4.25) 128 (5.04) 128 (5.04) 128 (5.04) D W1 70 56 (2.76) (2.20) 102 (4.16) 56 122 (4.80) (2.20) 129 (5.
STANDARD WIRING VS mini J7 DC REACTOR (OPTION) U X SHORT BAR MCCB 1 R/L1 S S/L2 T T/L3 FORWARD RUN/STOP U/T1 VS mini J7 V/T2 GROUNDING S2 FAULT RESET IM W/T3 S1 REVERSE RUN/STOP MULTIFUNCTION INPUT 2 R S3 EXTERNAL FAULT (NO CONTACT) MULTI-STEP SPEED REFERENCE 1 MA S4 MB RUNNING MC S5 MULTI-FUNCTION OUTPUT 250VAC 1A OR ESS 30VDC 1A OR LESS SC PULSE TRAIN INPUT FREQUENCY REFERENCE 2kΩ P P SHIELDED CONNECTION TERMINAL FS FREQUENCY SETTING POWER SUPPLY ( 12V 20mA) FR SPEED
CONSTANTS LIST Function Constant No. n== VS mini J7 Function Name Description Setting Range Min. Setting Unit Initial Ref.
CONSTANTS LIST (Cont'd) Function Selecting Acceleration/ Deceleration Time Constant No. n== Function Name 16* Acceleration time 1 17* 18* 19* Selecting S-curve Frequency Reference ( FREF ) Frequency Reference Limit Motor Protection by Electronic Thermal Selecting Cooling Fan Operation Description Sets acceleration time in the unit when frequency reference changes from 0 to 100 %. Setting Range Min. Setting Unit 0.0 to 999 Initial 10.0s 10.
Function Constant No. n== 36 Multi-function input selection 2 (Terminal S2) Selecting Sequence Input Functions Selecting Sequence Output Functions Selecting Frequency Reference Functions Min.
CONSTANTS LIST (Cont'd) Function Constant No. n== Function Name Description Setting Range Min. Setting Unit Initial Ref. Page Adjusting Carrier Frequency 46 Carrier frequency selection Carrier frequency 1, 2, 3, 4 : Set value ×2.5 Hz 7, 8, 9 : Proportional to output frequency of 2.5 kHz max.
Function Holding Output Frequency Torque Compensation Constant No. n== 62 Function Name Hold output frequecy saving selection Description Selects whether or not to save the frequency when holding at UP/DOWN command from multi-function input terminal. 0 : Output frequency is not saved while holding 1 : When holding more than 5 sec, saves output frequency at holding and operates at this frequency when restarted. Setting Range Min. Setting Unit Initial Ref. Page 0, 1 1 0 – 0.0 to 2.5 0.1 1.
PROGRAMMING FEATURES VS mini J7 The set value displayed in Programming features of VS mini J7 are explained according to the following items. is factory setting.
Motor rotation direction setting Operation mode selection FWD/REV direction selection F/R Run command selection Sets the motor rotation direction when run command is given by the digital operator. FWD and REV run can be switched by pressing ^ or v key. ( ) ( FWD RUN REV RUN ) LOCAL (operator)/REMOTE (control circuit terminal) selection LOCAL/REMOTE switching LO/RE Operation can be switched from digital operator or control circuit terminal. This function is valid only when stopped. e.g.
PROGRAMMING FEATURES (Cont’d) VS mini J7 The set value displayed in is factory setting. Setting Operating Condition 8-step speed change example n02 = 1 (Operation mode selection) n03 = 1 (Frequency reference selection) Reverse run prohibit Reverse run prohibit N05 “Reverse run disabled” setting does not accept a reverse run command from the control circuit terminal or digital operator. This setting is used for applications where a reverse run command can cause problems.
Adjusting frequency upper and lower limits Frequency reference gain N41 Frequency reference upper limit N30 Frequency reference bias N42 Frequency reference lower limit N31 When the frequency reference is output by analog input of control circuit terminals FR and FC, the relation between analog voltage and frequency reference can be set. FREQUENCY REF. Frequency reference gain (n41) The analog input voltage OUTPUT value for the maximum MAX.
PROGRAMMING FEATURES (Cont’d) VS mini J7 The set value displayed in Automatic restart after momentary power loss Torque detection Operation selection after momentary power loss N47 Overtorque detection function selection N59 When momentary power loss occurs, operation restarts automatically. Setting Description Continuous operation after momentary power loss not provided. 0 Continuous operation after power recovery within 0.5 second.
Frequency detection Operating coasting motor without trip Frequency detection level N58 Speed search command Input terminal function selection N36 to N39 DC injection braking at start N52 DC injection braking current DC injection braking time at start N54 Effective when output terminal function selections n40, are set to “frequency detection (setting : 4 or 5). “Frequency detection” turns ON when output frequency is higher or lower than the frequency detection level (n58).
PROGRAMMING FEATURES (Cont’d) VS mini J7 The set value displayed in is factory setting. Holding accel/decel temporarily Reducing motor noise or leakage current Accel/decel hold command Carrier frequency N46 Input terminal function selection N36 to N39 To hold acceleration, input accel/decel hold command. The output frequency is maintained when the aceel/decel hold command is input during acceleration or deceleration.
Selecting Method to Stop Building Interface Circuits with External Devices Operator stop key selection Using input signals Operator stop key selection N06 Input terminal function selection N36 to N39 Selects processing when STOP key is depressed during operation from control circuit terminal or communication. Multi-function input terminals S2 to S5 functions can be changed when necessary by setting constants n36 to n39, respectivery. The same value can not be set to different constant setting.
PROGRAMMING FEATURES (Cont’d) VS mini J7 The set value displayed in Terminal function at 3-wire sequence selection STOP SW (NC CONTACT) RUN SW (NO CONTACT) S1 RUN COMMAND (Run when “closed”) S2 STOP COMMAND (Stop when “open”) S3 FWD/REV RUN SELECTION FWD run when “open” SC REV run when “closed” ( is factory setting.
Adjusting Motor Torque Using output signals Adjusting torque according to application Multi-function output terminal function selection N40 Max. output frequency Max. voltage Max. voltage output frequency Mid. output frequency Mid. output frequency voltage Min. output frequency Min. output frequency voltage Torque compensation gain Multi-function output terminal MA and MB, functions can be changed when necessary by setting constants n40.
PROGRAMMING FEATURES (Cont’d) VS mini J7 The set value displayed in Preventing motor from stalling (Current limit) Stall prevention (current limit) level during accel N56 Stall prevention (current limit) level during running N57 N55 Stall prevention during decel Stall prevention (current limit) level during accel (n56) Automatically adjusts the output frequency and the output current according to the load to continue operation without stalling the motor.
Decreasing Motor Speed Fluctuation Motor Protection Slip compensation Motor overload detection Slip compensation gain N66 N32 Motor rated current Electronic thermal motor protection selection N33 Electronic thermal motor protection time constants setting N34 As the load becomes larger, the motor speed is reduced and motor slip value is increased when V/f control mode is selected. The slip compensating function controls the motor speed at a constant value even if the laod varies.
PROTECTIVE FUNCTIONS VS mini J7 : ON : BLINKING : OFF Alarms and Corrective Actions Alarm Display Digital RUN (Green) Operator ALARM (Red) Inverter Status BLINKING BLINKING BLINKING BLINKING Warning Does not output fault.
Faults and Corrective Actions Fault Display Digital RUN (Green) Operator ALARM (Red) Inverter Status Explanation Causes and Corrective Actions Check the following and restart: • Short-circuit or grounding at inverter output side • Excessive load GD2 • Extremely rapid accel/decel time (n16 to OC (overcurrent) n19) Inverter output current momentarily exceeds approx. 250 % • Special motor used of rated current.
PROTECTIVE FUNCTIONS (Cont’d) VS mini J7 Faults and Corrective Actions (Cont’d) Fault Display Digital RUN (Green) Operator ALARM (Red) Inverter Status Explanation EF (external fault) Received an external fault signal.
NOTES ON USE VS mini J7 Inverter Selection < Use a DC reactor (option) or an AC reactor (option) on the inverter power side when the inverter is connected directly to a large-capacity power transformer (600kVA and over within 10m distance) or when a phase advance capacitor is switched. Otherwise excess peak current may occur in the power feed circuit and the converter section may be damaged.
NOTES ON USE (Cont'd) VS mini J7 Peripheral Devices Installation and selection of molded-case circuit breaker On the input power side, a molded-case circuit breaker (MCCB) to protect inverter primary wiring should be installed. The inverter power-factor (depending on power voltage, output frequency, and load) must be taken into account for selecting MCCB. For standard settings, see page 36.
Noise Countermeasures The low-noise type uses high-carrier frequency PWM control, and compared to the low-carrier type tends to suffer from increased electromagnetic interference (EMI). Following are suggestions that may be effective in reducing EMI effects in your installation: • Lower the carrier frequency (constant n46) and the interference will be reduced. • A line noise filter is effective in eliminating sensor malfunction or AM radio static (see page 35).
NOTES ON USE (Cont'd) VS mini J7 Motor 25% ED (OR 15 MIN) 40% ED (OR 20 MIN) Application for Existing Standard Motors 60% ED (OR 40 MIN) 100 A standard motor driven by the inverter generates slightly less power than it does when it is driven with commercial power supply. Also, the cooling effect deteriorates in low speed range so that the motor temperature rise increases. Reduce load torque in the low speed range. Allowable load characteristics of the standard motor are shown in the figure.
OPTIONS AND PERIPHERAL UNITS VS mini J7 Power Supply Ref, page Name Model (Parts Code No.) Protection of inverter wiring Molded-case circuit braker (MCCB) or ground fault interrupter* NF30 To protect inverter wiring, always install it on the power supply side. Use a ground fault 36 interrupter with resistance to high frequencies. Controlling the power supply by sequence Magnetic contactor HI-?J Install to close/break the power circuit by sequence. Always use a surge suppressor on the coil.
OPTIONS AND PERIPHERAL UNITS (Cont’d) VS mini J7 Molded-Case Circuit Breaker (MCCB) and Magnetic Contactor (MC) Be sure to connect a MCCB between the power supply and the input AC reactor. Connect a MC if required. Molded-Case Circuit Breaker (MCCB) 200V Three-phase Input Series Motor Capacity kW VS mini J7 Model CIMR-J7?A? 0.1 0.2 0.4 0.75 1.5 2.2 3.
Isolator Allowance Temperature Influence Aux. Power Supply Influence ±0.25% of output span [Ambient temp : 23°C, (73.4°F)] With ±0.25% of output span [The value at ±10°C (±50°F) of ambient temp.] With ±0.1% of output span (The value at ±10% of aux. power supply) Load Resistance Influence Output Ripple Response Time Withstand Voltage Insulation Resistance With ±0.05% of output span (In the range of load resistance) With ±0.5%P-P of output span 0.5 sec.
OPTIONS AND PERIPHERAL UNITS (Cont’d) VS mini J7 DC Reactor (Model UZDA-B for DC circuit) Connection Example DC REACTOR U MCCB X +1 +2 MOTOR L1(R) L1(R) T1(U) L2(S) L2(S) T2(V) L3(T) L3(T) T3(W) 95-68088 IM VS mini J7 Take off the shorting bar between +1 and + 2, and wire as shown in the diagram. When power capacity is significantly greater when compared to inverter capacity, or when the powerfactor needs to be improved, connect the AC or DC reactor.
AC Reactor (Model UZBA-B for Input 50/60Hz) Connection Example AC REACTOR MCCB L1(R) L2(S) L3(T) U X V Y W Z MOTOR L1(R) T1(U) L2(S) T2(V) L3(T) T3(W) IM VS mini J7 Be sure to connect AC reactor on inverter input side [L1 (R), L2 (S), L3 (T)]. 96-72111 When power capacity is significantly greater when compared to inverter capacity, or when the power-factor needs to be improved, connect the AC or DC reactor. In order to supress high harmonic wave, DC reactor can be used with AC reactor.
OPTIONS AND PERIPHERAL UNITS (Cont’d) VS mini J7 Zero Phase Reactor Finemet Zero Phase Reactor to Reduce Radio Noise (Made by Hitachi Metals, Ltd.) 72±0.5 39.5 MIN 7 ±0.5 78 MAX Note: Finemet is a registered trademark of Hitachi Metals, Ltd. 3–M4 HEXAGON SOCKET 50±0.5 3–4.5DIA. 26 MAX 12.5±0.3 95 MAX 80±0.5 2–5.5DIA. Model F6045GB 200V Three-phase Input Series Inverter Recommended Model Wire Size mm2 CIMR-J7?A20P1 CIMR-J7?A20P2 2 CIMR-J7?A20P4 CIMR-J7?A20P7 CIMR-J7?A21P5 CIMR-J7?A22P2 3.
Input Noise Filter Example: Single-phase input (Model LNFB) R 692-383 VS mini J7 NOISE FILTER MCCB 1 2 S Three-phase input (Model LNFD) L1(R) 3 4 E L2(S) VS mini J7 NOISE FILTER MCCB T1(U) R T2(V) S R S U V L1(R) L2(S) T2(V) T L W E L3(T) T3(W) IM T3(W) T1(U) IM Noise Filter without Case Model Product Code Prats Codes No. Figure No. W D H A A’ B 0.3, 0.6 Rated Current A 10 LNFB-2102DY 72600-B2102DY FIL 128 1 120 (4.72) 80 (3.15) 50 (1.97) 108 (4.
OPTIONS AND PERIPHERAL UNITS (Cont’d) VS mini J7 Output Noise Filter Specifications (Tohoku Metal Industries Co., Ltd.) 200V Class (Three-phase) Example VS mini J7 MCCB L1(R) T1(U) R OUTPUT NOISE FILTER IN 1 4 S L2(S) T2(V) 2 5 T L3(T) T3(W) 3 6 Max. Applicable Motor Output kW (HP) Inverter Capacity kVA Model Rated Current A Part Code No. 0.1 (0.13) 0.3 LF-310KA 10 FIL 000068 0.2 (0.25) 0.6 LF-310KA 10 FIL 000068 0.4 (0.5) 1.1 LF-310KA 10 FIL 000068 0.75 (1) 1.
Digital Operator for Remote Operation (Model JVOP-146/144) Remote Interface Unit for Remote Operation (Model SI-232/J7) Interface Unit for Copy Unit (Model SI-232/J7C) Remote Interface Unit for Remote Operation (Model SI-232/J7) Interface Unit for Copy Unit* (Model SI-232/J7C) Dimensions in mm (inches) Digital Operator for Remote Operation (Model: JVOP-146) (15.5) STOP 1.7 5 (0.07) (0.2) 12.2 (0.48) 23.1 (0.91) 78 (3.07) 88 (3.
SERVICE NETWORK VS mini J7 Service Agency Serivce Area YASKAWA Subsidiary Service Location YASKAWA ELECTRIC EUROPE GmbH YASKAWA ELECTRIC AMERICA, INC. Europe, South Africa North, South, and Central America YEG YASKAWA ELECTRIC KOREA CORPORATION Korea YEK Frankfurt SAMSUNG ELECTRONICS CO., LTD. Korea SEC Shanghai Yaskawa Tongji M & E Co., Ltd. SSC East China Seoul Los Angels TAIAN ELECTRIC CO., LTD.
VS mini J7 IRUMA BUSINESS CENTER 480, Kamifujisawa, Iruma, Saitama 358-8555, Japan Phone 81-42-962-5696 Fax 81-42-962-6138 YASKAWA ELECTRIC AMERICA, INC. 2121 Norman Drive South, Waukegan, IL 60085, U.S.A. Phone 1-847-887-7000 Fax 1-847-887-7370 MOTOMAN INC. HEADQUARTERS 805 Liberty Lane West Carrollton, OH 45449, U.S.A. Phone 1-937-847-6200 Fax 1-937-847-6277 YASKAWA ELETRICO DO BRASIL COMERCIO LTD.A.