YASKAWA AC Drive Compact V/f Control Drive J1000 100 V CLASS, SINGLE-PHASE INPUT: 0.1 to 1.1 kW 200 V CLASS, THREE-PHASE INPUT: 0.1 to 5.5 kW 200 V CLASS, SINGLE-PHASE INPUT: 0.1 to 2.2 kW 400 V CLASS, THREE-PHASE INPUT: 0.2 to 5.
Reliable Smart Small but Reliable Easy to Operate and So Compact RoHS compliant YASKAWA AC Drive J1000 Compact V/f Control Drive 2
Reliability the world has come to expect from Yaskawa as a global leader is now packed into an even smaller, more powerful unit. So easy to use: just switch it on and you're ready to go. J1000 is fully capable of efficient performance and energy saving, handling variable speed needs in compact applications. A drive that exemplifies true world quality with a difference you can really feel.
Features 1. Fully Equipped with User and Environmentally-Friendly Functions Compact Design Every drive has dual rating, Normal Duty (ND) and Heavy Duty (HD). Parameter settings let the user select the rating that best suits the application needs. Selecting ND allows the drive to operate a more powerful motor an entire frame size larger than with HD. Side-by-Side installation and J1000's impressively compact design make it possible to fit the entire setup into a the narrowest enclosures.
YASKAWA AC Drive J1000 Compact V/f Control Drive 2. Features Features Ensuring Stable Operation Starts Heavy Loads Effortlessly Enhanced Braking Fully automatic torque compensation across the entire speed range, whether accelerating, decelerating, or operating at constant speed. Capable of 100% rated torque as low as 1.5 Hz, and 150% at 3 Hz when set for Heavy Duty performance. The overexcitation braking functions enables rapid braking up to 50% faster without using a braking resistor.
Features 3. True Reliability and Top Quality Assurance Hassle-free Maintenance Convenient Parameter Management Yaskawa drives have a built-in maintenance timer that keeps track of component performance, including capacitors, softcharge circuitry, IGBTs, and the cooling fan. This ensures maximum performance life of the drive. The cooling fan is also designed for quick replacement: both detachable and easily accessible from the top of the drive.
YASKAWA AC Drive J1000 Compact V/f Control Drive Features Wide Range of Options Available Information Features 4. Compatible with a Single-Phase, 100 V Power Supply available soon DriveWizard Plus*2 Yaskawa offers J1000 for both industry and home use with the availability of a single-phase 100 V model. DriveWizard Plus makes it possible to operate the drive and perform maintenance using a PC.
Application Benefits J1000 gets the most out of the application. Fluid Applications Advantages 1 The Setup Mode saves valuable installation time by providing just the essential parameters needed to get Functions the application running immediately. 2 3 4 5 6 Normal Duty keeps the cost of the application down by allowing the use of a larger motor. 7 8 8 Speed Search prevents loss from down time by keeping the application running smoothly through a power loss.
Application Benefits Conveyor, Transport, and Civil Applications Advantages 1 2 3 The Setup Mode saves valuable installation time by providing just the essential parameters needed to get the application running immediately. Functions SET UP Mode ND/HD Selection Overexcitation Braking Heavy Duty provides high overload capability for reliable operation without production loss from down time.
Software Functions Loaded with software functions just right for your application. New Functions New software available to upgrade from J7 to J1000, automatically matching function and sequence settings. Note: Major functions listed below. Setup SET UP Mode Reference Functions Easy access to the minimumrequired parameters during setup. Save valuable time during setup by calling up just the parameters needed. Protect parameter settings.
V/f Pattern Characteristics Set a V/f pattern suited for the motor characteristics. Select the V/f pattern freely to gain optimal motor torque with any load condition. Phase Order Change Reverse Prevention Swing PWM Torque Compensation Slip Compensation Electronic Thermal Overload Frequency Detection Easily change the direction of motor rotation. Change the direction of motor rotation more easily with parameter settings rather than reversing output phase cables to the motor.
Parameter List Refer to J1000 Installation & Start-Up Manual for details. Function Initialization Parameters Operation Mode Selection DC Injection Braking Acceleration and Deceleration Times S-Curve Characteristics Slip Compensation Torque Compensation Carrier Frequency Frequency Reference Frequency Upper and Lower Limits Jump Frequency Frequency Reference Hold V/f Pattern Characteristics 12 No.
Motor Parameters Multi-Function Digital Inputs Multi-Function Digital Outputs Analog Inputs Multi-Function Analog Outputs MEMOBUS/Modbus Communications Motor Protection Functions Momentary Power Loss Stall Prevention Functions Frequency Detection Fault Reset Overtorque Detection Hardware Protection Hunting Prevention High-Slip Braking Display Settings Operator Keypad Functions Copy Functions Maintenance Period No. Name Range Default 10 to 200% of drive rated current *2 0.00 to 20.
Basic Instructions Quick Setup, Easy to Operate Operator Names and Functions Data display (5-digit) LED panel Displays frequency, parameter number, and other data. More information listed below. RUN light LO/RE light Lights when the Run command is present. Lights to indicate that the operator is set for LOCAL. RUN key LO/RE key Issues a Run command. Determines where the Run command and frequency reference come from: the keypad (LOCAL) or the control terminals (REMOTE).
Operation Example Using the LED Operator to Run the Drive Drive Mode: Run and Stop commands, displays operation status such as the frequency reference, output frequency, output current, output voltage, etc. How to Monitor the Frequency Reference Steps 2 Steps Result/Display Turn the power on. Key Result/Display Increase or decrease the value displayed. “End” appears while the drive saves the new data. Use the arrow keys to select the digits to set. Set the drive for LOCAL. LO should light.
Product Lineup Number in parenthesis indicates the rated output current. Motor Capacity kW Single-Phase 100 V Normal Duty 0.1 Three-Phase 200 V Heavy Duty Normal Duty Single-Phase 200 V Heavy Duty Normal Duty CIMR-JA2A0001 (0.8 A) CIMR-JAAA0001 Heavy Duty Three-Phase 400 V Normal Duty Heavy Duty CIMR-JABA0001 (0.8 A) 0.2 CIMR-JAAA0001 CIMR-JAAA0002 CIMR-JA2A0001 (1.2 A) CIMR-JA2A0002 (1.6 A) CIMR-JABA0001 (1.2 A) CIMR-JABA0002 (1.6 A) 0.
Model Selection Optimizing Control for Each Application J1000 offers two separate performance ratings: Normal Duty and Heavy Duty. Heavy Duty is capable of creating more powerful torque, while Normal Duty allows the drive to operate a larger motor.
Standard Specifications Parameter C6-01 sets the drive for Normal Duty or Heavy Duty performance. Value in brackets is for a single-phase drive. 200 V Class (Three-Phase/Single-Phase) Model Three-Phase CIMR-JA2A 0001 0002 0004 0006 0008 0010 0012 0018 0020 Single-Phase*1 CIMR-JABA 0001 0002 0003 0006 – 0010 – – – Input Max.
Common Specifications Control Method V/f Control Frequency Control Range 0.01 to 400 Hz Digital input: within ±0.01% of the max. output frequency (−10 to +50˚C) Analog input: within ±0.1% of the max. output frequency (25˚C ±10˚C) Digital input: 0.01 Hz Analog input: 1/1000 of max.
Standard Connection Diagram Standard Connection Diagram Example: 200 V Class * 1 DC reactor (option) Terminals +1, +2, − , B1, and B2 are for connecting options. Never connect power supply lines to these terminals. 2MCCB r1 s1 t1 For single-phase 200 V power supply, use R/L1 and S/L2.
Terminal Functions Main Circuit Terminals Terminal Function (Signal Level) Terminal Name R/L1 S/L2 T/L3 Main circuit power supply input Connects line power to the drive. Drives with single phase 100 V input or single phase 200 V input power use terminals R/L1 and S/L2 only (do not use T/L3). Drive output Connects to the motor. Braking resistor Available for connecting a braking resistor. DC reactor connection These terminals are shorted for shipment.
Dimensions Enclosures Standard J1000 uses an open-chassis design (IP20). NEMA 1 kits are available to convert the standard IP20 design to a NEMA Type 1 enclosure rating.
■ Enclosure Panel【NEMA Type1】 W1 W Model Class CIMR-JA 2A0001B 200 V Class (ThreePhase) 200 V Class (SinglePhase) 400 V Class (ThreePhase) 2A0002B 2A0004B 2A0006B 2A0008B 2A0010B 2A0012B 2A0018B 2A0020B BA0001B BA0002B BA0003B BA0006B BA0010B 4A0001B 4A0002B 4A0004B 4A0005B 4A0007B 4A0009B 4A0011B Figure 1 2 1 2 2 D D1 Figure 2 Dimensions (mm) W H 68 68 68 68 108 108 108 140 140 68 68 68 108 108 108 108 108 108 108 108 140 148 148 148 148 148.9 148.9 148.9 148.9 148.9 148 148 148 148.
Drive Watts Loss Data Normal Duty Ratings Model 200 V Class (ThreePhase) Model 200 V Class (SinglePhase) Model 400 V Class (ThreePhase) Model Number CIMR–JA2A Motor Capacity Rated Output Current Heat Loss kW A Heatsink W Internal W Total Heat Loss W Model Number CIMR–JABA Motor Capacity Rated Output Current Heat Loss kW A Heatsink W Internal W Total Heat Loss W Model Number CIMR–JA4A Motor Capacity Rated Output Current Heat Loss kW A Heatsink W Internal W Total Heat Loss W 0001 000
Attachment for External Heatsink Additional attachments required for installation. Final dimensions are taller than drive height. Mounting surface Cooled air ALM REV DRV FOUT RESET ENTER RUN STOP Wall ESC LO RE 100 min Dimensions (Heatsink for a 200 V 0.4 kW drive) 2A0001 2A0002 2A0004 2A0006 2A0008 2A0010 2A0012 2A0018 2A0020 BA0001 BA0002 BA0003 BA0006 D1 D2 D3 min Cooled air 100 min BA0010 4A0001 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 Dimensions (mm) Code No. D1 D2 D3 69.
Peripheral Devices and Options Power Supply Name Circuit Breaker Circuit Breaker (MCCB), Fusible disconnect Ground Fault Interruptor Ground Fault Interruptor (GFI) Purpose Protects circuitry from excessive current. Choose a GFI designed for use with a frequency meter. Magnetic Contactor Magnetic Contactor Interrupts the power supply to the drive. Surge Protector Absorbs the voltage surge from switching of electro-magnetic contactors and control relays.
Circuit Breaker, Magnetic Contactor Base device selection on motor capacity. Circuit Breaker Magnetic Contactor [Mitsubishi Electric] [Fuji Electric] Three-Phase 200 V Class 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.
Peripheral Devices and Options (continued) Surge Protector Dimensions (mm) 68 Mounting hole specifications 2-4 Dia. MTG holes Lead 2 50 26 2-3 tapped Lead 910 9 0.8 Dia. 30 24 22.5 30 18 Dia. 36 Weight: approx. 22 g Model: DCR2-50A22E 33 7 4.8 Dia. 16 16 76 Weight: approx. 5 g Model: DCR2-10A25C 34 Weight: approx. 150 g Model: RFN3AL504KD Product Line [Nippon Chemi-Con Corporation] Surge Protector Peripheral Devices Large-Capacity Coil (other than relay) Model Specifications Code No.
DC Reactor (UZDA-B for DC circuit) Base device selection on motor capacity. Connection Diagram 4000 DC Reactor U X Circuit Breaker Reactor required +2 Power Supply Capacity 600 (kVA) Reactor unnecessary 60 400 Drive Capacity (kVA) 0 +1 R/L1 S/L2 T/L3 R S T U/ T1 V/ T2 W/ T3 Motor M J1000 Note: Remove jumper between +1 and +2, and wire as shown in the diagram. Note: Reactor recommended for power supplies larger than 600 kVA. Use an AC reactor if power supply is 0.2 kW or smaller.
Peripheral Devices and Options (continued) AC Reactor (UZBA-B for Input 50/60 Hz) Base device selection on motor capacity. Connection Diagram AC Reactor Circuit Breaker U R V S W T X R/L1 S/L2 T/L3 Y Z Motor U/ T1 V/ T2 W/ T3 M J1000 Note: When using low noise type drives (high-carrier frequency of 2.5 kHz or more ) , do not connect an AC reactor to the output side (U, V, W) of the drive.
Zero Phase Reactor Base device selection on motor capacity. Finemet Zero-Phase Reactor to Reduce Radio Noise [Hitachi Metals, Ltd.] Note: Finemet is a registered trademark of Hitachi Metals, Ltd. Connection Diagram Example: Connection to output terminal J1000 Power Supply Close-up of V/T2-phase Wiring Zero Phase Reactor R/L1 U/T1 S/L2 V/T2 1st pass 2nd pass M 3rd pass T/L3 W/T3 4th pass Pass each wire (U/T1, V/T2, W/T3) through the core 4 times.
Peripheral Devices and Options (continued) Fuse/Fuse Holder 48 [Fuji Electric] Insulation R6 cover 14 3012 54 M10 φ 11 * 70 131 116 102 62 105 94 82 M6 * 5 Dia. 35 8 Dia. Dimensions (mm) 6 Dia. Install a fuse to the drive input terminals to prevent damage in case a fault occurs. 4 R8 Insulation cover Figure 1 6 13 21 35 72 Figure 2 : Mounting components supplied separately. Tighten bolt when fuse is installed.
Input Noise Filter without Case Base device selection on motor capacity. Connection Diagram Circuit Breaker R S Note: Contact Yaskawa for CE compliant models ( EMC directive). J1000 Noise Filter 1 2 3 4 E Circuit Breaker R/L1 U/T1 S/L2 V/T2 W/T3 M Noise Filter R S T R S T Single-Phase Input (LNFB Type) U V W E J1000 R/L1 U/T1 S/L2 V/T2 T/L3 W/T3 M Three-Phase Input (LNFD Type) Note: Do not connect the input noise filter to the drive output terminals (U, V, W).
Peripheral Devices and Options (continued) Input Noise Filter with Case Base device selection on motor capacity. Connection Diagram Circuit Breaker Note: Contact Yaskawa for CE compliant models (EMC directive). J1000 Noise Filter R S 1 2 3 4 E Circuit Breaker R/L1 U/T1 S/L2 V/T2 W/T3 Noise Filter R S T M R S T Single-Phase Input (LNFB Type) U V W E J1000 R/L1 U/T1 S/L2 V/T2 T/L3 W/T3 M Three-Phase Input (LNFD Type) Note: Connect in parallel when using two filters.
Output Noise Filter Base device selection on motor capacity. Connection Diagram Dimensions J1000 MCCB A C E Output Noise Filter F IN R R/L1 U/T1 1 4 S S/L2 V/T2 2 5 T T/L3 W/T3 3 6 H G M B D [NEC TOKIN Corporation] Three/Single-Phase 200 V Class Rated Model 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 LF-310KA LF-310KA FIL000068 LF-310KA LF-310KA FIL000068 LF-310KA LF-320KA FIL000068 LF-320KA LF-350KA FIL000069 FIL000070 Code No. FIL000068 FIL000068 FIL000069 Qty.
Peripheral Devices and Options (continued) Isolator (Insulation Type DC Transmission Converter) Connection Diagram Cable Length Input ・4 to 20 mA: within 100 m ・0 to 10 V: within 50 m 6 5 4 3 7 8 1 2 Load Power Supply Terminal Description 1 Output + 2 Output 3 4 Input + 5 Input 6 Grounding 7 Power Supply 8 Dimensions (mm) Model GP Series 50 110 100 78 10 Adjuster Position of the Potentiometer varies according to the model. Socket 50 40p0.2 4 3 7 8 1 2 View of Socket Mounting 23.
Braking Resistor, Braking Resistor Unit Base device selection on motor capacity. To use the optional braking resistor, dis*: able the deceleration stall prevention Braking Resistor Braking Resistor Unit Thermal Relay Trip Contact Use sequencer to break power supply side on overload relay trip contact.
Peripheral Devices and Options (continued) Braking Resistor, Braking Resistor Unit (continued) Braking Resistor Dimensions (mm) 44 13 1.2 5 182 170 150 Weight: approx. 0.2 kg (All ERF-150WJ Series models) 5p0.
RS-232C Interface for remote operator (Model: SI-232/J) Dimensions (mm) For SI-232/J and SI-232/JC For remote operation with the LED Operator, or for operation with DriveWizard Plus, use this interface unit. Code No. 100-041-094 13.2 30 Model SI-232/J 37.5 54 RS-232C Interface for copy unit/PC communication (Model: SI-232/JC) To use the USB copy unit, the LED Operator as a copy unit, or DriveWizard Plus, use this detachable interface unit. Model SI-232/JC Code No. 100-041-095 2.
Peripheral Devices and Options (continued) Frequency Meter/Current Meter Dimensions (mm) Note: DCF-6A is 3 V, 1 mA, 3 kΩ. For J1000 multi-function analog monitor output, set frequency potentiometer or parameter H4-02 (multi-function analog output terminal AM gain) within 0 to 3 V (default is 0 to 10 V). 65 24 24 60 53 24 24 24 2-M4 Terminal Screws 4-M3 MTG Bolts Weight: approx. 0.3 kg 4-4 Dia. 24 24 12.5 30 12 0.5 10 24 Code No.
Application Notes Installation Application Notes 適用上のご注意 ■ Enclosure Panels Selection Keep the drive in a clean environment by either selecting ■ Installing a Reactor An AC or DC reactor can be used for the following: drive in an enclosure panel. Be sure to leave the required ・ to suppress harmonic current. ・ to smooth peak current that results from capacitor space between the drives to provide for cooling, and that proper measures are taken so that the ambient temperature switching.
Application Notes (continued) General Handling ■ Wiring Check other components. Avoid switching the MC more than once every 30 minutes. The MC will not be activated Never connect the power supply lines to output terminals after a momentary power loss if using the operator U/T1, V/T2, or W/T3. Doing so will destroy the drive. Be keypad to run the drive. This is because the drive is sure to perform a final check of all sequence wiring and unable to restart automatically when set for LOCAL.
■ Wire Gauges and Wiring Distance ■ Leakage Current Motor torque can suffer as a result of voltage loss across a Harmonic leakage current passes through stray long cable running between the drive and motor, especially capacitance that exists between the power lines to the when there is low frequency output. Make sure that a large drive, ground, and the motor lines. Consider using the enough wire gauge is used.
Application Notes (continued) ■ High Speed Operation Problems may occur with the motor bearings and ■ Explosion-proof Motor dynamic balance in applications operating at over 60 Both the motor and drive need to be tested together to be certified as explosion - proof. The drive is not for Hz. Contact Yaskawa for consultation. explosion proof areas.
Power Driven Machinery (decelerators, belts, chains, etc.) Continuous operation at low speeds wears on the lubricating material used in gear box type systems to accelerate and decelerate power driven machinery. Caution should also be taken when operating at speeds above the rated machine speed due to noise and Application Notes shortened performance life.
YASKAWA AC Drive Series Name Capacity Range (kW) 0.1 1 10 100 300 Feature Single-Phase 0.1 100 V Class*1 Three-Phase J1000 Compact V/f Control 200 V Class Drive Single-Phase 200 V Class Three-Phase 400 V Class Outline ・Ultra-small body enables side-by-side installation. 1.1 0.1 5.5 0.1 2.2 0.2 Compact design of enclosure panel ・Easy operation with the Potentiometer Option Unit ・The noise-suppressing Swing PWM system reduces harsh sound.
Global Service Network 5 6 Frankfurt San Francisco Los Angels 1 Chicago 9 10 11 Boston New Jersey 12 North Carolina Seoul Shanghai 13 Taipei Tokyo 7 8 17 Mumbai 2 Mexico City 16 Bangkok Singapore 4 Santafe De Bogota 14 15 3 Sao Paũlo 18 Sydney Melbourne North America South America Europe Service Area Service Location U.S.
J1000 IRUMA BUSINESS CENTER (SOLUTION CENTER) 480, Kamifujisawa, Iruma, Saitama 358-8555, Japan Phone 81-4-2962-5696 Fax 81-4-2962-6138 YASKAWA ELECTRIC AMERICA, INC. 2121 Norman Drive South, Waukegan, IL 60085, U.S.A. Phone 1-847-887-7000 Fax 1-847-887-7370 YASKAWA ELETRICO DO BRASIL LTDA.