Instruction manual

Initial setting
73
No.
Terminal
Initial Setting
n050
n051
n052
n053
n054
n055
n056
S1
S2
S3
S4
S5
S6
S7
1
2
3
5
6
7
10
Function
Forward run command (2-wire sequence)
Reverse run command (3-wire sequence)
External fault
Fault reset
Multi-step speed reference 1
Multi-step speed reference 2
JOG command
Terminal function at 3-wire sequence selection
When 0 is set at the terminal S3 (n052), terminal S1 becomes run command,
terminal S2 becomes stop command, and terminal S3 becomes FWD/REV
run command.
LOCAL/REMOTE selection (setting: 17)
Select operation reference either by the digital operator or by the settings of
run command selection (n003) and frequency reference selection (n004).
LOCAL/REMOTE select is available only during stop.
Open : Run according to the setting of run command selection (n003) or
frequency reference selection (n004).
Closed : Run by frequency reference and run command from the digital
operator.
Run command
(Run when closed)
Stop command
(Stop when open)
FWD/REV run selection
FWD run when open
REV run when closed
STOP SW
(NC CONTACT)
RUN SW
(NO CONTACT)
S1
S2
S3
SC
( )
VS-606V7