Instruction manual

63
To hold acceleration or deceleration, input accel/decel hold command. The
output frequency is maintained when the accel/decel hold command is input
during acceleration or deceleration.
When the stop command is input during accel/decel prohibition command
input, accel/decel hold is released and operation ramps to stop.
Set multi-function input selection (n050 to n056) to 16 (accel/decel
prohibit).
Time chart at accel/decel hold command input
Note : When the FWD (REV) run command is input along with the accel/decel hold command,
the motor does not operate. However, when frequency reference lower limit (n034) is
set greater than or equal to min. output frequency (n016), the motor operates at
frequency reference lower limit (n034).
Holding accel/decel temporarily
FWD (REV)
RUN COMMAND
ACCEL/DECEL
HOLD COMMAND
FREQUENCY
REFERENCE
OUTPUT
FREQUENCY
FREQUENCY
AGREED
SIGNAL
ON
ONONON
ON
ON