Instruction manual
169
Notes:
4. Changes depending on inverter capacity. Refer to page 67.
5. Initial setting of the model with digital operator JVOP-140 (with potentiometer) is 0.
Setting can be set to 1 by constant initialization.
2. Upper limit of setting range and initial setting are doubled at 400V class.
1. Not initialized by constant initialization.
3. Changes depending on inverter capacity. Refer to the next page.
No.
6. When control mode selection (n002) is changed, initial setting corresponds to the control mode.
* Values are doubled with 400V class.
Name
V / f control mode
(n002 = 0)
Vector control mode
(n002 = 1)
n014 Mid. output frequency 1.3Hz
n015 Mid. output frequency voltage 12.0V*
n016 Min. output frequency 1.3Hz
n017 Min. output frequency voltage 12.0V*
n104 Torque compensation time constant 0.3s
n111 Slip compensation gain 0.0
n112 Slip compensation gain time constant 2.0s
3.0Hz
11.0V*
1.0Hz
4.3V*
0.2s
1.0
0.2s
7.
Changes depending on inverter capacity. Refer to page 101.
No.
< 200V class 3-phase
Name Unit
– Inverter capacity kW 0.1kW 0.25kW 0.55kW 1.1kW 1.5kW 2.2kW – 4.0kW
n036 Motor rated current A 0.6 1.1 1.9 3.3 6.2 8.5 – 14.1
n105
Torque compensation
iron loss
W 1.7 3.4 4.2 6.5 11.1 11.8 – 19
n106 Motor rated slip Hz 2.5 2.6 2.9 2.5 2.6 2.9 – 3.3
n107
Line to neutral
(per phase)*
Ω 17.99 10.28 4.573 2.575 1.233 0.8 – 0.385
n108
Motor leakage inductance
MH 110.4 56.08 42.21 19.07 13.4 9.81 – 6.34
n110 Motor no-load current % 72 73 62 55 45 35 – 32
No.
< 200V class single-phase
Name Unit
Initial Setting
Initial Setting
– Inverter capacity kW 0.1kW 0.25kW 0.55kW 1.1kW 1.5kW 2.2kW – 4.0kW
n036 Motor rated current A 0.6 1.1 1.9 3.3 6.2 8.5 – 14.1
n105
Torque compensation
iron loss
W 1.7 3.4 4.2 6.5 11.1 11.8 – 19
n106 Motor rated slip Hz 2.5 2.6 2.9 2.5 2.6 2.9 – 3.3
n107
Line to neutral
(per phase)*
Ω 17.99 10.28 4.573 2.575 1.233 0.8 – 0.385
n108
Motor leakage inductance
MH 110.4 56.08 42.21 19.07 13.4 9.81 – 6.34
n110 Motor no-load current % 72 73 62 55 45 35 – 32
Initial settings that change with the inverter capacity