Instruction manual

165
109 016D
Torque compensation
voltage limitter
0 to 250%
150%
1%
111 016F
Slip compensation gain
0.0 to 2.5
0.0
0.1
112 0170
Slip compensation time
constant
Stall prevention automatic
decrease selection
Accel / decel time during
stall prevention
0.0 to 25.5s
2.0s
0.1s
113 0171
0173
0174
Slip correction during
regenerative operation
0, 1
0
1
110 016E
Motor no-load current
0 to 99%
(Note 3)
1%
86
86
84
85
0, 1
0
1
0, 1
0
1
45
115
#2
116
#2
103 0167
Torque compensation gain
0.0 to 2.5
1.0
0.1
104 0168
Torque compensation
time constant
0.0 to 25.5s
0.3s
44
44
0.1s
105 0169
Torque compensation iron
loss
0.0 to 6550
(note 3)
0.01W (less than
1000W) /
1W (1000W or
more)
107 016B
Line to neutral (per phase)
0.000 to 65.50
(note 3)
0.001 (less than
10) /
0.01 (10 or
more)
108 016C
Motor leakage inductance
0.00 to 655.0mH
(note 3)
0.01mH (less
than 100mH) /
0.1mH (100mH
or more)
106 016A
44
46
46
46
Motor rated slip
0.0 to 20.0Hz
(note 3)
0.1Hz
No.
Name
Setting
Range
Register
No. for
Trans-
mission
Setting
Unit
Initial
Setting
User
Setting
Ref.
Page
101
#3
0165
Speed search deceleration
time
0.1 to 10.0s 2.0s
0.1s 62
117
#3
0175
Undertorque detection
function selection 1
0 to 4 0
1 126
118
#3
0176
Undertorque detection level 0 to 200%
10%1% 126
119
#3
0177
Undertorque detection time 0.1 to 10.0s 0.1s0.1s
126
102
#3
0166
Speed search operation
level
0 to 200% 150%
1% 62