Instruction manual
163
Second Functions (Constants n050 to n079)
No.
Name
Setting
Range
Register
No. for
Trans-
mission
Setting
Unit
Initial
Setting
User
Setting
Ref.
Page
050 0132
Multi-function input
selection 1 (Terminal S1)
1
1
051 0133
Multi-function input
selection 2 (Terminal S2)
1
2
052 0134
Multi-function input
selection 3 (Terminal S3)
1
3
053 0135
Multi-function input
selection 4 (Terminal S4)
1
5
054 0136
Multi-function input
selection 5 (Terminal S5)
1
6
055 0137
Multi-function input
selection 6 (Terminal S6)
1
7
056 0138
Multi-function input
selection 7 (Terminal S7)
1
10
057 0139
Multi-function output
selection 1
1
0
058 013A
Multi-function output
selection 2
1
1
059 013B
Multi-function output
selection 3
1
2
060 013C
Analog frequency
reference gain
0 to 255%
1%
100%
061 013D
Analog frequency
reference bias
-100 to 100%
1%
0%
062
065
013E
0141
Monitor output type
Filter time constant for
analog frequency
reference constant
0.00 to 2.00s
0.01s
0.10s
066 0142
Multi-function analog
output (terminal AM-AC)
0 to 5, 6#3
0,1
1
1
0
0
067
068
069
070
071
072
0143
0144
0145
0146
0147
0148
Analog monitor gain
Analog frequency
reference gain
Analog frequency
reference bias
Analog frequency
reference filter time
constant
Analog frequency reference
gain
-255 to 255%1%
-100 to 100%
0.00 to 2.00s
-255 to 255
1%
1%
0.01s
1%
100%
0%
0.10s
100%
-100 to 100% 1% 0%
Analog frequency
reference bias
0.00 to 2.00
0.01
1.00
73
73
73
73
73
73
73
78
78
78
53
53
–
64
65
64
–
–
–
–
–
0 to 7, 8#3, 9#3,
10 to 19, 20#3, 21#3
0 to 7, 8#3, 9#3,
10 to 19, 20#3, 21#3
0 to 7, 8#3, 9#3,
10 to 19, 20#3, 21#3
064
#3
0140
Frequency reference loss
detection selection
0,1
1
0
123
1 to 25, 26#3,
27#3
1 to 25, 26#3,
27#3
1 to 25, 26#3,
27#3
1 to 25, 26#3,
27#3
1 to 25, 26#3,
27#3
1 to 25, 26#3,
27#3
1 to 25
, 26#3,
27#3
, 34, 35
073 0149
Analog frequency
reference filter time
constant
0.00 to 2.00s
0.01s
0.01s
074 014A
Pulse train frequency
reference gain
0 to 255%
1%
100%
075 014B
Pulse train frequency
reference bias
-100 to 100%
1%
0%
076 014C
Pulse train frequency
filter time constant
0.00 to 2.00s
0.01s
0.10s
–
–
–
–