Instruction manual

147
200V single- / 3-phase
RUN and ALARM provided as standard LED's
Available to monitor frequency reference,
output frequency, output current
Main circuit: screw terminals
Control circuit: plug-in screw terminal
100m (328ft) or less
Open chassis IP20, Open chassis IP20 (Top-closed type),
or enclosed wall-mounted NEMA 1 (TYPE 1)
Open chassis IP20 : -10 to +50°C (14 to 122°F)
Open chassis IP20 (Top-closed type) and enclosed
wall-mounted NEMA 1 (TYPE 1)
: -10 to +40°C (14 to 105°F)
(not frozen)
95%RH or less (non-condensing)
-20 to +60°C (-4 to 140°F)
Indoor (free from corrosive gases or dust)
1000m (3280ft) or less
Up to 9.8m / S
2
(1G) at 10 to less than 20Hz,
up to 2m / S
2
(0.2G) at 20 to 50Hz
Environmental
Conditions
Cooling fan is provided for the following models:
200V, 0.75kW or larger inverters (3-phase)
200V, 1.5kW or larger inverters (single-phase)
Other models are self-cooling
Voltage Class
Other Functions
Display
Model
CIMR-V7
*
C????
3-
phase
Status Indicator
LED
Digital Operator
(JVOP-140)
Terminals
Wiring Distance
between Inverter
and Motor
Enclosure
Cooling Method
Ambient Temperature
Humidity
Storage Temperature
Location
Elevation
Vibration
20P1
B0P1
20P2
B0P2
20P4
B0P4
20P7
B0P7
21P5
B1P5
22P2 24P0
B2P2 B4P0
Single-
phase
Temperature during shipping (for short period)
For details, refer to Reducing motor noise or leakage current (n080) on page 57.