• Sequence Circuit Configuration and Timing Chart Examples
For the AC sequence circuit,
connect the signal between P1 and
PC to the sequence circuit with a
relay.
Design the sequence so that the
hoiding brake contact is open
when the sequense operation
conditions are satisfied and the
contact between P1 and PC is
closed(ON).
Make sure that the holding brake
contact is closed when the
emergency stop signal or inverter
fault contact output signal is ON.
• For V/f Control and Vector Control
• For a variable speed operation by an analog signal, set the frequency reference selection
(n004) to a value from 2 to 4.
Frequency
detection 1
INVERTER VS-606V7
(Forward run)
(Reverse run)
(Multi-step speed reference 2)
Sequence
circuit
Energizes the brake when ON
(30 VDC 1 A or less)
Holding brake
auxiliary relay coil
+24V
MA
UP
DOWN
HIGH/LOW
BR
MB
MC
SC
S6
S2
S1
P1
PC
Fault contacts
Input
Output
Output Frequency
0
Frequency
detection 1
(n058=4)
Holding
brake
operation
Time
DC injection brake
High speed/
Low speed
UPS1 – SC
S6 – SC
P1 – PC
ONOFF
ON
ON
OPENCLOSE CLOSE
OFF
n095
n095
OFF
n026
n024 (Enabled when n004=1)