Instruction manual
The software No. (of the inverter whose constants stored in the digital
operator are read out) is displayed.
119
Explanation
Operator display
• Enable the setting for the
constans n001 to n179.
• Execute Inverter Capacity
Display (vA) by Constant
copy function selection (n176)
• Press DSPL to light [PRGM].
• Press ENTER to display the
set value.
• Change the set value to 4 by
Pressing or key.
• Press ENTER.
• Change the constant No. to
n176 by pressing or key.
• Press ENTER to display the
set value.
• Change the set value to vA fy
by pressing or key.
• Press ENTER.
• Press DSPL or ENTER.
N001
(Can be a different constant No.)
1 (Lit)
(Can be a different constant No.)
4 (Bl inks)
4 (Lit for one second)
↓
N001 (The constant No. is
displayed)
N17 6
DY (Lit)
VR (Lit)
20.7 (Lit) (For 20P7) ∗
N176 (The constant No. is
displayed)
v
v
v
v
v
v
Explanation
Operator display
• Enable the setting for the
constans n001 to n179.
• Execute Software No. Display
(Sno)∗ by Constant copy
function selection (n176).
• Press DSPL to light [PRGM].
• Press ENTER to display the
set value.
• Change the set value to 4 by
Pressing or key.
• Press ENTER.
• Change the constant No. to
n176 by pressing or key.
• Press ENTER to display the
set value.
• Change the set value to Sno by
pressing or key.
• Press ENTER.
• Press DSPL or ENTER.
N001
(Can be a different constant No.)
1 (Lit)
(Can be a different set value.)
4 (Bl inks)
4 (Lit for one second)
↓
N001 (The constant No. is
displayed)
N176
DY (Lit)
SNO (Lit)
0013 (Lit)
(software version : VSP010013)
N176 (The constant No. is
displayed)
∗ Displays Lower 4 digits of the software version.
[Example] Display the software No. of the inverter whose constants
stored in EEPROM inside the digital operator
v
v
v
v
v
v
Software No. Display