Instruction manual

The voltage class and maximum applicable motor capacity (whose constants
stored in the digital operetor are read out) are displayed.
[Example] Display the voltage class and maximum applicable motor capacity for
the inverter whose constants stored in EEPROM inside
the digital operator
118
Explanation
Operator display
Enable the setting for the
constans n001 to n179.
Execute Inverter Capacity
Display (vA) by Constant
copy function selection (n176)
Press DSPL to light [PRGM].
Press ENTER to display the
set value.
Change the set value to 4 by
Pressing or key.
Press ENTER.
Change the constant No. to
n176 by pressing or key.
Press ENTER to display the
set value.
Change the set value to vA fy
by pressing or key.
Press ENTER.
Press DSPL or ENTER.
N001
(Can be a different constant No.)
1 (Lit)
(Can be a different constant No.)
4 (Bl inks)
4 (Lit for one second)
N001 (The constant No. is
displayed)
N17 6
DY (Lit)
VR (Lit)
20.7 (Lit) (For 20P7)
N176 (The constant No. is
displayed)
v
v
v
v
v
v
Inverter Capacity Display
Explanation
Operator display
Display the unmatched
constant No.
Display the constant value in
the inverter.
Display the constant value in
the digital operator.
Continue the execution of
VERIFY.
Press ENTER.
Press ENTER.
Press key.
Press DSPL or ENTER.
N01 1 (Blinks) (When n011 is
unmatched)
60.0 (Blinks)
50.0 (Blinks)
VFY (Blinks while executing
VERIFY)
END(End is displayed when the
execution of VERIFY is completed).
N176
(The constant No. is displayed)
v
While an unmatched constant No. is displayed or a constant value is displayed,
pressing STOP/RESET interrupts the execution of VERIFY and End is displayed.
Pressing DSPL or ENTER returns to the constant No.