Instruction manual
The voltage class and maximum applicable motor capacity (whose constants
stored in the digital operetor are read out) are displayed.
[Example] Display the voltage class and maximum applicable motor capacity for
the inverter whose constants stored in EEPROM inside
the digital operator
118
Explanation
Operator display
• Enable the setting for the
constans n001 to n179.
• Execute Inverter Capacity
Display (vA) by Constant
copy function selection (n176)
• Press DSPL to light [PRGM].
• Press ENTER to display the
set value.
• Change the set value to 4 by
Pressing or key.
• Press ENTER.
• Change the constant No. to
n176 by pressing or key.
• Press ENTER to display the
set value.
• Change the set value to vA fy
by pressing or key.
• Press ENTER.
• Press DSPL or ENTER.
N001
(Can be a different constant No.)
1 (Lit)
(Can be a different constant No.)
4 (Bl inks)
4 (Lit for one second)
↓
N001 (The constant No. is
displayed)
N17 6
DY (Lit)
VR (Lit)
20.7 (Lit) (For 20P7) ∗
N176 (The constant No. is
displayed)
v
v
v
v
v
v
Inverter Capacity Display
Explanation
Operator display
• Display the unmatched
constant No.
• Display the constant value in
the inverter.
• Display the constant value in
the digital operator.
• Continue the execution of
VERIFY.
• Press ENTER.
• Press ENTER.
• Press key.
• Press DSPL or ENTER.
N01 1 (Blinks) (When n011 is
unmatched)
60.0 (Blinks)
50.0 (Blinks)
VFY (Blinks while executing
VERIFY)
↓
END(End is displayed when the
execution of VERIFY is completed).
N176
(The constant No. is displayed)
v
While an unmatched constant No. is displayed or a constant value is displayed,
pressing STOP/RESET interrupts the execution of VERIFY and End is displayed.
Pressing DSPL or ENTER returns to the constant No.