Instruction manual
10. Specifications
243
018 0112 Selecting Setting Unit for
Acceleration/decelera-
tion Time
0, 1 1 0 144
019 0113 Acceleration Time 1 0.00 to
6000 s
Depend on
n018 setting
10.0 s 143
020 0114 Deceleration Time 1 0.00 to
6000 s
Depend on
n018 setting
10.0 s 143
021 0115 Acceleration Time 2 0.00 to
6000 s
Depend on
n018 setting
10.0 s 143
022 0116 Deceleration Time 2 0.00 to
6000 s
Depend on
n018 setting
10.0 s 143
023 0117 S-curve Selection 0 to 3 1 0 145
024 0118 Frequency Reference 1
(Master Speed Fre-
quency Reference)
(Note 6)
0 to 9999
r/min
1 r/min 180 r/min 139
025 0119 Frequency Reference 2
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 139
026 011A Frequency Reference 3
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 139
027 011B Frequency Reference 4
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 139
028 011C Frequency Reference 5
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 139
029 011D Frequency Reference 6
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 139
030 011E Frequency Reference 7
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 139
031 011F Frequency Reference 8
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 139
032 0120 Jog Frequency
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 141
033 0121 Frequency Reference
Upper Limit (Note 6)
0% to
110%
1% 100% 142
034 0122 Frequency Reference
Lower Limit (Note 6)
0% to
110%
1% 0% 142
035 0123 Setting/displaying Unit
Selection for Frequency
Reference
0 to 3999 1 4 196
036 0124 Motor Rated Current 0% to
150% of
Inverter
rated cur-
rent
0.1 A (Note 3) 172
037 0125 Electronic Thermal Mo-
tor Protection Selection
0 to 2 1 0 172
038 0126 Electronic Thermal Mo-
tor Protection Time Con-
stant Setting
1 to 60 min 1 min 8 min 172
No. Register
No. for
Trans-
mission
Name Setting
Range
Setting Unit Factory
Setting
User
Setting
Ref.
Page