Instruction manual

6. Operating with DeviceNet Communications
121
Monitor Data (Read-only Registers)
Register
Number
Contents
0020H Status signals
Bit 0 Forward run
1: Run
0: Stop
1 Reverse run
1: Reverse run
0: Forward run
2 Inverter ready for operation
3Fault
4 Data setting error
1: Error
5 Multi-function output 1
1: MA ON
6 Multi-function output 2
1: P1 ON
7 Multi-function output 3
1: P2 ON
8 to F Not used.