Pn00B
Application Function Select Switch B 0000 to 1111 − 0000 After restart Setup
Pn00C
Application Function Select Switch C 0000 to 0111 − 0000 After restart Setup
(cont’d)
Parameter
No.
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
0
1
Alarm Gr.2 Stop Method Selection
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Stops the motor by setting the speed reference to "0".
Same setting as Pn001.0 (Stops the motor by applying DB or by coasting)
0
1
Power Supply Method for Three-phase SERVOPACK
Three-phase power supply
Uses three-phase input specification as single-phase power supply.
0
1
Parameter Display Selection
Setup parameters
All parameters
Semi-closed Encoder Usage Method (Rotational servomotors)
Uses the encoder connected to the SERVOPACK.
Uses the encoder connected to the feedback option module.
0
1
Reserved (Do not change.) (Linear servomotors)
0
1
Encoder Resolution for Test without Motor (Rotational servomotors)
Reserved (Do not change.)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
13 bits
20 bits
0
1
Selection of Test without Motor
Disables test without motor.
Enables test without motor.
0
1
Encoder Type for Test without Motor
Incremental encoder (Rotational servomotors)
Incremental linear scale (Linear servomotors)
Absolute encoder (Rotational servomotors)
Absolute linear scale (Linear servomotors)