User`s manual
10 Appendix
10-6
PnB13
/INPOSITION 0 to 3 – 0 After restart 5.3.7
PnB14
/POUT0 0 to 1 – 0 After restart 5.3.8
PnB15
/POUT1 0 to 1 – 0 After restart 5.3.8
PnB16
/POUT2 0 to 1 – 0 After restart 5.3.8
PnB17
/POUT3 0 to 1 – 0 After restart 5.3.8
PnB18
/POUT4 0 to 1 – 0 After restart 5.3.8
PnB19
/POUT5 0 to 1 – 0 After restart 5.3.8
PnB1A
/POUT6 0 to 1 – 0 After restart 5.3.8
PnB1B
/POUT7 0 to 1 – 0 After restart 5.3.8
(cont’d)
Parameter
No.
Name Setting Range
Setting
Unit
Factory
Setting
When
Enabled
Reference
Setting Meaning
0 When positioning has been completed, photocoupler becomes ON (close).
1 When positioning has been completed, photocoupler becomes OFF (open).
Setting Meaning
0 When programmable output signal /POUT0 is active, photocoupler becomes ON (close).
1 When programmable output signal /POUT0 is active, photocoupler becomes OFF (open).
Setting Meaning
0 When programmable output signal /POUT1 is active, photocoupler becomes ON (close).
1 When programmable output signal /POUT1 is active, photocoupler becomes OFF (open).
Setting Meaning
0 When programmable output signal /POUT2 is active, photocoupler becomes ON (close).
1 When programmable output signal /POUT2 is active, photocoupler becomes OFF (open).
Setting Meaning
0 When programmable output signal /POUT3 is active, photocoupler becomes ON (close).
1 When programmable output signal /POUT3 is active, photocoupler becomes OFF (open).
Setting Meaning
0 When programmable output signal /POUT4 is active, photocoupler becomes ON (close).
1 When programmable output signal /POUT4 is active, photocoupler becomes OFF (open).
Setting Meaning
0 When programmable output signal /POUT5 is active, photocoupler becomes ON (close).
1 When programmable output signal /POUT5 is active, photocoupler becomes OFF (open).
Setting Meaning
0 When programmable output signal /POUT6 is active, photocoupler becomes ON (close).
1 When programmable output signal /POUT6 is active, photocoupler becomes OFF (open).
Setting Meaning
0 When programmable output signal /POUT7 is active, photocoupler becomes ON (close).
1 When programmable output signal /POUT7 is active, photocoupler becomes OFF (open).