91
[How to Operate]
Refer to “23.9 File Settings”.
The automatic backup function is available for the following files:
・
Ladder files (*.LST)
・
CMOS files (*.HEX)
・
Name files (*.NAM)
A file name of one of these backup files has an “_” (under score) after each file
extension in the same folder as the original files:
Relevant file name + extension + “_”
23.6 Rough Draft File Forced Output Function
Ladder Editor 32NX stores only the ladder programs in which compiling and
grammatical checks, etc. are completed normally. However, the procedure may be
interrupted temporarily during editing. To store a ladder program that cannot be
compiled during editing, it can be forcibly stored as a rough draft file.
[How to Operate]
1. Select [File] – [Save As Rough Draft].
2. When the [Save File] dialog box appears, use an arbitrary file name to store it.
Note: Even if the reading source is a CMOS file, a work file can only output a text
file as a ladder program file.
23.7 Automatic Updating Function
If an attempt to move to another line is made without selecting [Line Alt] or [Line
Insert] when the data has been edited in the “ladder editing” display, one can select
whether the [Verification] dialog box appears or the line is to be updated
automatically.
For automatic updating, select either [Overwrite Current Rung] or [Insert New
Rung].