6.3 Storing Edited Data
When ladder editing is completed, store the information in a file. Before storing,
compile the data when a ladder was edited by Ladder Editor 32NX. Unless
compiled, data may not be stored completely.
[How to Operate]
1. Selecting [File] – [Save] stores the overwritten data on an existing file.
2. Selecting [File] – [Save As] displays the [Save As] dialog box. Set an
arbitrary file name to the data to be stored.
To store the file, the following three types of file forms are available, depending on
the method used to read in a file.
6.3.1 Storing when a Ladder Program File (CIOPRG.LST) is Open
When a ladder program file is read in, only a ladder program file (text file) can be
stored in an output file form.
6.3.2 Storing when a CMOS File (CMOS.HEX) is Open
When a CMOS file is read in, the data can be stored in the two types of file forms,
a ladder program file (text file) and a CMOS file (binary file), as an output file.
6.3.3 Storing a Ladder Program that is Being Edited
A ladder program being edited cannot be stored if it has a detected error, even if
compiled. The ladder program being edited can be stored as a work file
. For