Operator`s manual

2.1 I/O Instructions
2-24
2. ON/OFF
When an AT#(anticipation output number) is selected from the table in part 1 of this Explana-
tion, add the following tag.
Settings for the anticipation output signal
Set the number of the output signal for the anticipation output in the ANTICIPATION OUT-
PUT display.
cOT OUTPUT (Setting range: 1 to 192)
Allocate the number of the general-purpose output whose signal timing is to be
adjusted to AT NO. 1 to 4.
dON TIME (Setting range: -327.68 to 327.67 seconds)
Set the delay/advance time for turning ON the signal.
eOFF TIME (Setting range: -327.68 to 327.67 seconds)
Set the delay/advance time for turning OFF the signal.
fOG OUTPUT (Setting range: 1 to 24)
Allocate the group number of the general-purpose output whose signal timing is
to be adjusted to AG NO. 1 and 2.
gTIME (Setting range: -327.68 to 327.67 seconds)
Set the delay/advance time for carrying out the group output.
No. Tag Explanation Note
3
ON/OFF Specifies the ON/OFF status of the signal whose
output timing is adjusted.
SUPPLE-
MENT
<SINGLE>
1
2
3
4
1
2
OTOUTPUT
ONTIME
OFFTIME
OGOUTPUT
-0.50
-0.50
-0.50
-0.50
-0.50
-0.50
-0.80
-0.20
-0.50
-0.70
010
11
12
13
10
11
ATNO.
<GROUP>
AGNO.
TIME
c
d
f
e
g
DATA
EDIT
DISPLAY
UTILITY
MainMenu ShortCut
ANTICIPATIONOUTPUT