Operator`s manual
2.1 I/O Instructions
2-20
ARATIOF
Instruction set:
Cancels the analog output corresponding to the speed.
1. AO# (Analog output port number)
Add the following tag.
ARATIOF AO#(1)
The analog output corresponding to the speed at the analog output port number 1 is can-
celled.
SUBSET STANDARD EXPANDED
Not available Available Available
No. Tag Explanation Note
1
AO# (Analog out-
put port number)
Specifies the number of the general-purpose
analog output port for which the analog output
corresponding to speed is to be cancelled.
No.: 1 to 40
Variable B/I/D/LB/LI/
LD can be used.
Function
Construction
ARATIOF
AO# (
Analog output
port No.
)
END
1
Explanation
Example