Operator`s manual
2.1 I/O Instructions
2-15
AOUT
Instruction set:
Outputs the set voltage value to the general-purpose analog output port.
1. AO# (Analog output port number)
Add the following tag.
2. Output voltage value
Add the following tag.
SET I000 1270
AOUT AO#(1) I000
The voltage of 12.7 V is output to the analog output port No. 1.
SUBSET STANDARD EXPANDED
Not available Available Available
No Tag Explanation Note
1
AO# (Analog out-
put port number)
Specifies the number of the analog output port to
which the set voltage value is output.
No.: 1 to 40
Variable B/I/D/LB/LI/
LD can be used.
No. Tag Explanation Note
2
Output voltage
value
Specifies the output voltage value. Voltage value:
-14.00 to +14.00
Variable I/LI/I[]/LI[]
can be used.
(Units: 0.01 V)
Function
Construction
AOUT
AO# (
Analog output
port No.
)
Output voltage
value (V)
1 2
END
Explanation
Example