Operator`s manual

2.1 I/O Instructions
2-14
3. T=Time
The following tag can be added or omitted.
(1) PULSE OT#(128)
The pulse signal is output for 0.30 seconds to general output signal No.128.
(2) SET B000 5
PULSE OT#(B000) T=1.0
The pulse signal is output for 1.0 seconds to general output signal No.5.
(3) SET B000 24
PULSE OG#(3) B000
B000=24 (Decimal)=00011000 (Binary)
The pulse signal is output for 0.30 seconds to the general output signal No.’s 20 and
21.
No. Tag Explanation Note
6
T=Time Specifies the time during which the pulse signal
is output.
The pulse signal is output during the specified
time T.
Units: seconds
Variable I/LI/I[]/LI[]
can be used.
(Units: 0.01 seconds)
When the time is not
specified, the pulse
signal is output dur-
ing 0.30 seconds.
Example
Pulse signal
0.3sec
Pulse signal
ON
OFF
1.0 sec
OT#(17)OT#(23) OT#(22)
OG#(3)
OT#(21)OT#(24) OT#(19) OT#(18)
ON
OT#(20)