Operator`s manual
2.1 I/O Instructions
2-13
1. OT# (output number) / OG# (output group number) / OGH# (output group
number)
Choose one of the tags from the following table.
2. B Variable number / LB Variable number / B [Array number] / LB [ Array
number] / Byte type constant
When OG# (output group number) or OGH# (output group number) in the above table is
selected, choose one of the tags from the following table.
No Tag Explanation Note
1
OT# (Output No.) Specifies the number of the signal to which the
pulse signal is output.
No.: 1 to 1024
Variable B/I/D/LB/LI/
LD can be used.
2
OG# (Output
group No.)
Specifies the group number of the signal (1
group 8 points) to which the pulse signal is out-
put.
No.: 1 to 128
Variable B/I/D/LB/LI/
LD can be used.
3
OGH# (Output
group No.)
Specifies the group number of the signal (1
group 4 points) to which the pulse signal is out-
put.
No.: 1 to 256
Variable B/I/D/LB/LI/
LD can be used.
No. Tag Explanation Note
4
B Variable number/
LB Variable number/
B [Array Number] /
LB [Array Number]
Specifies the number of the corresponding pulse
output signal when the contents of the specified
byte type variable is expressed in bits.
Bit:
0: OFF
1: ON
5
Byte type constant Specifies the number of the corresponding pulse
output signal when the specified byte type con-
stant is expressed in bits.
Explanation