Operator`s manual
2.1 I/O Instructions
2-8
1. IN#(Input number) / OT#(Output number) / SIN#(Specific input number) /
SOUT#(Specific output number) / IG#(Input group number) / OG#(Output
group number) / IGH#(Input group number) / OGH#(Output group number)
/ B Variable Number / LB Variable Number / B [Array Number] / LB [Array
Number]
Choose one of the tags from the following table.
No Tag Explanation Note
1
IN# (Input num-
ber)
Specifies the number of the general input signal
for the waiting condition.
No:1 to 1024
Variable B/I/D/LB/LI/
LD can be used.
2
OT# (Output
number)
Specifies the number of the general output signal
for the waiting condition.
No:1 to 1024
Variable B/I/D/LB/LI/
LD can be used.
3
SIN# (Specific
input number)
Specifies the number of the specific input signal
for the waiting condition.
No:1 to 640
Variable B/I/D/LB/LI/
LD can be used.
4
SOUT# (Specific
output number)
Specifies the number of the specific output signal
for the waiting condition.
No:1 to 800
Variable B/I/D/LB/LI/
LD can be used.
5
IG#(Input group
number)
Specifies the number of general input group (1
group 8 points) signal for the waiting condition.
No:1 to 128
Variable B/I/D/LB/LI/
LD can be used.
6
OG#(Output
group number)
Specifies the number of general output group (1
group 8 points) signal for the waiting condition.
No:1 to 128
Variable B/I/D/LB/LI/
LD can be used.
7
IGH#(Input group
number)
Specifies the number of general input group (1
group 4 points) signal for the waiting condition.
No:1 to 256
Variable B/I/D/LB/LI/
LD can be used.
8
OGH#(Output
group number)
Specifies the number of general output group (1
group4 points) signal for the waiting condition.
No:1 to 256
Variable B/I/D/LB/LI/
LD can be used.
9
B Variable num-
ber/
LB Variable num-
ber/
B [Array number]/
LB [Array num-
ber]
Specifies the byte type variable for the waiting
condition.
Explanation