Operator`s manual
2.8 Handling Instruction
2-260
2. Hand number
Add the following tag.
3. B Variable number/LB Variable number/B [Array number]/LB [Array num-
ber]/ON/OFF
Choose one of the tags from the following table.
4. ALL
The following tag can be added or omitted.
HAND 1 OFF
Turns OFF the signal output to tool valve 1.
No. Tag Explanation Note
5
Hand number Specifies the hand number. No.: 1 to 4
Variable B/I/D/LB/LI/
LD can be used.
No. Tag Explanation Note
6
B Variable num-
ber/LB Variable
number/
B [Array number]/
LB [Array num-
ber]
Refers the least significant bit of the specified
byte type variable to specify the ON/OFF status
of the signal to be sent to the tool valve.
Least significant bit:
0: OFF
1: ON
7
ON/OFF Specifies the ON/OFF status of the signal to be
sent to the tool valve.
No. Tag Explanation Note
8
ALL Specifies the simultaneous control of Valve 1 and
Valve 2.
Used when a 3P
solenoid is used.
Example