Operator`s manual
2.7 Arc Welding Instruction
2-254
(1) ARCCTS AC=150 AV=16.0 DIS=100.0
MOVL V=80
To make the welding current =150A and arc voltage =16V, the current and the volt-
age are changed in the section of 100mm from the move start point.
Gradually Decreasing Current or Voltage
Gradually Increasing Current or Voltage
(2) ARCCTS AC=150 AV=16.0 AN3=7.50 AN4=6.50 DIS=100.0
To make the welding current =150A, arc voltage =16V, aimed value =7.5V of the
instruction voltage to analog output 3, and aimed value =6.5V of the instruction volt-
age to analog output 4, the current and the voltage are changed in the section of
100mm from the move start point.
Example
Value immediately before execution
of move instruction
ARCCTS aimed value
ARCCTSexecuted
Welding continues
DIS =100
Move distance specified
by move instruction
Value
immediately before
execution of move instruction
ARCCTS aimed value
ARCCTSexecuted
Welding continues
DIS=100
Move distance specified
by move instruction