Operator`s manual

2.7 Arc Welding Instruction
2-253
4. AN3=Aimed value of instruction voltage
The following tag can be added or omitted.
5. AN4=Aimed value of instruction voltage
The following tag can be added or omitted.
6. DIS=Execution section
The following tag can be added or omitted.
No Tag Explanation Note
8
AN3=Aimed value
of instruction volt-
age
Specifies the aimed value of the instruction volt-
age to analog output 3.
Aimed value:
-14.00 V to +14.00 V
Variable I/I[]/LI/LI[]
can be used.
(Units: 0.01 V)
No Tag Explanation Note
9
AN4=Aimed value
of instruction volt-
age
Specifies the aimed value of the instruction volt-
age to analog output 4.
Aimed value:
-14.00 V to +14.00 V
Variable I/I[]/LI/LI[]
can be used.
(Units: 0.01 V)
No Tag Explanation Note
10
DIS=Execution
section
Specifies the execution section where the cur-
rent and the voltage are changed.
The execution section is set by the distance from
the moving start point.
If the section is not specified, all the section of
the move instruction is regarded as the execu-
tion section.
Section: 0.1 mm to
6553.5 mm
Variable B/I/D/B[]/I[]/
D[]/LB/LI/LD/LB[]/
LI[]/LD[] can be used.
(Units: 0.1 mm)
Slope up/down function
The slope up/down function allows for the current and the voltage value etc., during weld-
ing to be gradually changed.
This function is used when the base metal is a board, or when the object is an aluminum
which has high heat conductivity.
In this function, the ARCCTS and the ARCCTE instruction are used.
For details of the slope up/down function, refer to the “Operator’s Manual for the Arc Weld-
ing”.
SUPPLE-
MENT