Operator`s manual

2.7 Arc Welding Instruction
2-247
Wearing conditions
• Weaving single amplitude
Set the amplitude of oscillation.
• Weaving angle
Set the angle of oscillation.
• Direction of oscillation
The directions, “forward” and “reversed”, are defined as follows. Set “0 (forward)” or “1
(reversed)” for the direction of oscillation.
SUPPLE-
MENT
Singleamplitude
Angle
Angle: 0.1 deg. to 180.0 deg.
Weaving mode: Single oscllation
Wall direction
Horizontal
direction
Horizontal
direction
Angle: 0.1 deg. to 180.0 deg.
Wall direction
Weaving mode: Triangular or L-shape oscillation
Virtical
distance
Angle
Horizonal distance
Wall direction
Horizontal
direction
Single
oscillation
Forward
Reversed
Trianglar
oscillation
L-shape
oscillation
Wall direction
Wall direction Wall direction
Wall direction Wall direction
Forward
Forward
Reversed
Reversed

Horizontal
direction
Horizontal
direction
Horizontal
direction
Horizontal
direction
Horizontal
direction