Operator`s manual

2.7 Arc Welding Instruction
2-236
2. Voltage command value /I Variable number /LI Variable number /I [Array
number] /LI [Array number]
Choose one of the tags from the following table.
(1) VWELD 6.0
The command value of the arc voltage is set to 6.0V.
(2) SET I000 500
VWELD I000
Set to 5.0V to which the command value of the arc voltage is set with I000.
No Tag Explanation Note
5
Voltage com-
mand value
Specifies the command value of the arc voltage.
This is a command value of the voltage which is
transmitted from the controller to the welder to
output the welding voltage from the welder. The
relation between the command welding voltage
and the output value is different depending on
the model of the welder.
Command value:
-14.00 V to +14.00 V
Variable I/LI/I[]/LI[]
can be used.
(Units: 0.01 V)
6
I Variable num-
ber/
LI Variable num-
ber/
I [Array number]/
LI [Array number]
Specifies the integer type variable number by
which the command value of the arc voltage is
set.
For details of the output characteristics of the welder, refer to the “Operator’s Manual for
Arc Welding”.
SUPPLE-
MENT
Example