Operator`s manual
2.7 Arc Welding Instruction
2-232
2. AEF# (Arc end condition file number) /AC=Current output value
Choose one of the tags from the following table.
3. AV=Voltage output value /AVP=Ratio to proper voltage output value
When AC=Current output value is selected from the table in part 2 of this Explanation, choose
one of the tags from the following table.
4. T=Time
When AC=Current output value is selected from the table in part 2 of this Explanation, the fol-
lowing tag can be added or omitted.
No Tag Explanation Note
5
AEF#(Arc end
condition file
number)
Specifies the arc end condition file number.
The condition when welding has ended is regis-
tered in the arc end condition file.
No. : 1 to 12
Variable B/I/D/LB/LI/
LD can be used.
6
AC=Current out-
put value
Specifies the output value of the welding current. Current value:
1 to 999A
Variable B/I/D/B[]/I[]/
D[]/LB/LI/LD/LB[]/
LI[]/LD[] can be used.
No Tag Explanation Note
7
AV=Voltage out-
put value
Specifies the output value of the arc voltage.
When the welder power supply is ’Individual’ the
output value of the arc voltage is specified.
Voltage value: 0.1 V
to 50.0 V
Variable B/I/D/B[]/I[]/
D[]/LB/LI/LD/LB[]/
LI[]/LD[] can be used.
(Units: 0.1 V)
8
AVP=Ratio to
proper voltage
output value
Specifies the ratio to the aptitude output value of
the arc voltage.
When the welder power supply is ’Same’ the
ratio to the aptitude output value of the arc volt-
age is specified.
Ratio: 50% to 150%
Variable B/I/D/B[]/I[]/
D[]/LB/LI/LD/LB[]/
LI[]/LD[] can be used.
No Tag Explanation Note
9
T=Time Specifies the timer value at welding end. Unit: Seconds
Variable I/LI/I[]/LI[]
can be used.
(Units: 0.01 seconds)