Operator`s manual

2.7 Arc Welding Instruction
2-227
1. WELD1/WELD2/WELD3/WELD4
Choose one of the tags from the following table. These tags are valid for a system with multi-
ple applications in which two or more arc welding applications are included. These tags are
not displayed when there is only one application.
2. ASF# (Arc start condition file number) /AC=Current output value
Choose one of the tags from the following table.
3. AV=Voltage output value /AVP=Ratio to proper voltage output value
When AC=Current output value is selected from the table in part 2 of this Explanation, choose
one of the tags from the following table.
No Tag Explanation Note
1
WELD1 Specifies Welder 1.
2
WELD2 Specifies Welder 2.
3
WELD3 Specifies Welder 3.
4
WELD4 Specifies Welder 4.
No Tag Explanation Note
5
ASF#(Arc start
condition file
number)
Specifies the arc start condition file number.
The condition when the welding begins is regis-
tered in the arc start condition file.
No: 1 to 48
Variable B/I/D/LB/LI/
LD can be used.
6
AC=Current out-
put value
Specifies the output value of the welding current. Current value: 1 to
999A
Variable B/I/D/B[]/I[]/
D[]/LB/LI/LD/LB[]/
LI[]/LD[] can be used.
No Tag Explanation Note
7
AV=Voltage out-
put value
Specifies the output value of the arc voltage.
When the welder power supply is ’Individual’, the
output value of the arc voltage is specified.
Voltage value:
0.1V to 50.0 V
Variable B/I/D/B[]/I[]/
D[]/LB/LI/LD/LB[]/
LI[]/LD[] can be used.
(Units: 0.1V)
8
AVP=Ratio to
proper voltage
output value
Specifies the ratio to the aptitude output value of
the arc voltage.
When the welder power supply is ’Same’, the
ratio to the aptitude output value of the arc volt-
age is specified.
Ratio: 50% to 150%
Variable B/I/D/B[]/I[]/
D[]/LB/LI/LD/LB[]/
LI[]/LD[] can be used.
Explanation