1.2 Registration of Instructions
1-4
< Example >
TIMER tag (T=)
TIMER T=I000
When a variable is used for the numeric data of the TIMER tag, the unit of numeric data is
0.01
seconds.
When 1000 is set for I000, the value when the instruction is executed is 10.00 seconds.
1.2 Registration of Instructions
1.2.1 Registration
Press [INFORM LIST] while the job content window is shown to register instructions.
Operation Explanation
1 Select {JOB} under the main
menu
2 Select {JOB} The job content window appears.
3 Press [INFORM LIST] The job instruction group list dialog box appears.
4 Select the desired instruction
group
The job instruction list dialog box appears.
INFORM
LIST
JOB
EDIT
DISPLAY
UTILITY
MainMenu ShortCut
JOBCONTENT
JOBNAME:R1S1
CONTROLGROUP:R1+S1
STEPNO:004
TOOL:00
0017TIMERT=1.00
0018MOVJVJ=12.50
0019MOVJVJ=50.00
0020MOVLV=138
0021MOVLV=138
0022MOVJVJ=100.00
0023DOUTOT#(1)ON
IN/OUT
OTHER
CONTROL
DEVICE
MOTION
ARITH
SHIFT
SAME
PRIOR
=>
JOB
EDIT
DISPLAY
UTILITY
MainMenu
ShortCut
JOBCONTENT
JOBNAME:R1S1
CONTROLGROUP:R1+S1
STEPNO:004
TOOL:00
=>
ARATIOF
DOUT
DIN
WAIT
PULSE
IN/OUT
OTHER
CONTROL
DEVICE
MOTION
ARITH
SHIFT
SAME
PRIOR
AOUT
ARATION
=>
DOUTOT#(1)ON
0017TIMERT=1.00
0018MOVJVJ=12.50
0019MOVJVJ=50.00
0020MOVLV=138
0021MOVLV=138
0022MOVJVJ=100.00
0023DOUTOT#(1)ON