1.1 About INFORM
1-2
1.1.3 Instruction Set
To improve operation efficiency, the number of instructions to be registered is limited. All
instructions are executed, regardless of the instruction set during playback, etc.
• Subset Instruction Set
Only high instructions which are used frequently are in the subset instruction set. The
number of instructions is small, which allows for easier selecting and input.
• Standard Instruction Set / Expanded Instruction Set
All INFORM II instructions can be registered. For these two sets, the number of additional
items which can be used by each instruction is different. The following function cannot be
used with a standard instruction set, but operation is easier because the number of data
decreases when the instruction is registered.
• Local Variable, Use of Array Variable
• Use of Variable to Additional Item (Ex. : MOVJ VJ=I000)
Selecting Instruction Set
Select an instruction set in the teaching condition window.
Operation Explanation
1 Select {SETUP} under the
main menu
2 Select {TEACHING COND} The teaching condition window appears.
DATA
EDIT
DISPLAY
UTILITY
MainMenu
ShortCut
TEACHINGCONDITION
MRESET
RECT/CYLINDRICAL
LANGUAGELEVEL
INSTRUCTIONINPUTLEARNING
MOVEINSTRUCTIONSET
STEPONLYCHANGING
RECT
SUBSET
VALID
LINE
PROHIBIT