Tool info file (memory)
Address Item Details
+0000 Status
0: Initial value, 1: Run instruction, 16: In-process,
256: Normal completion, 4096: Error
+0001 Line count
Number of lines in the obtained file
Protocol is updated after send is complete.
+0002 Save location 0: Memory
+0003 File type 2: Tool info file
+0004 Starting address USER area address for the output destination
+0005 Starting line
Starting Tool number 0 - 63
If a number is designated where no data exists, the output result will be
filled with 0x00.
+0006 Character count
Ignored (20-byte reserved)
If a number is designated where no data exists, the output result will be
filled with 0x00.
Overflow Excess is truncated.
+0007
Number of
output lines
Number of tools to load 1 - 64
If a number is designated where no data exists, the output result will be
filled with 0x00.
+0008 -
+0025
File name Ignored (TOOL.CND reserved)
+0026 Folder name Ignored