6. Placement of Sensors
General tips on placement
Try to place the sensors in discrete locations
Place sensors along walls at about
150-170 cm (60-70 inches) from floor
Sensors are attached using screws or adhesive tape
Target wood, plastic, or metal surfaces that are flat
Avoid wall papers as they may break if sensor must be removed
Avoid painted walls when using adhesive tape as modern paint is efficient in repelling adhesive
tape
Remove tape cover and press firmly ON THE SLEEVE for 10 seconds. After 10 seconds, the
adhesive tape is strong enough to hold the sensor. Full adhesiveness is reached after 72 hours.
Yanzi Motion+
Place on wall of smaller rooms such as conference rooms and phone booths
Place in ceiling above groups of 4-8 work desks
Yanzi Comfort
Place on wall not close to work desk
Requires a power outlet within 0.5 meters (longer cables available as accessory)
Yanzi Presence for work desks
Place under work desk about an arm’s length from edge
Yanzi Presence for conference room chairs
Place under conference room table at each chair about an arms length from edge
Yanzi Presence for conference room corner
Place in corner of smaller rooms and along walls in larger rooms
Face away from windows to avoid direct sunlight
Face away from door to avoid detecting people walking outside the room
Use multiple sensors for large rooms (>20m
2
)