Specifications
System Specifications
Items Model Number Remarks
KMG65E-S3
KMG65E-K3
KMG65E-S6
KMG65E-K6
Quantity of
Connected Power
Box(es)
— 1 2
Continuous
Output
kVA 3.0 6.0 (3.0 and 3.0)
kW 3.0 6.0 (3.0 and 3.0)
Power Factor — 1.0
Maximum Output kVA 3.2 6.4 (3.2 and 3.2)
Output for Engine
Speed
See Figure 1
Start / Stop — ON / OFF Switch on Control Panel
Warning Signal LED Light
ON
Generator Temperature (Stator)
Power Box Temperature
Overload See Figure 1
Insufficient Engine Speed
Self Protection Function Auto Stop for Overheat and Overload
Engine Speed Versus Power Output
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
0 500 1000 1500 2000 2500 3000 3500
Engine Speed
Output A
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Output kVA
Maximum output
Continuous output
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
0 500 1000 1500 2000 2500 3000 3500
Engine Speed RPM
Overload
Output A
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Output kVA
Maximum output
Continuous output
Maximum output
Continuous output
POWER CAN BE SUPPLIED
SPEED IS INSUFFICIENT
0004622
Figure 1
SPECIFICATIONS
40 KMG65E Operation Manual