Specifications
PRODUCT OVERVIEW
JH Series Operation Manual 29
12/05
Accessory power output
The harness attached to the panel has a terminal where the signal that is synchronized to
the panel power supply can be taken off. (Figure 17) (Refer to the Wiring Diagrams on
page 117.)
The maximum current of this output terminal is 3 A (Fuse capacity). Do not use a current
higher than 3 A.
For the content of the output terminal, refer to the Wiring Diagrams on page 117.
Figure 8
Figure 17
043801-01EN00
F1A - 3 AMP Fuse
Buzzer
ACC Output
4JH45_4JH57_4JH80_4JH110_EN_OPM.book 29 ページ 2013年10月8日 火曜日 午後3時58分