Specifications
18
2. PRODUCT EXPLANATION
EN
2.5 Control Equipment
The equipment in the control room, mak-
ing remote control possible, consists of the
instrument panel, which is connected by
wire harness and the remote control han-
dle, which is hooked up by remote control
cables to the engine control lever and ma-
rine gear.
2.5.1 Instrument Panel
2.5.1.1 Controls and equipment
The instrument panel is located in the con-
trol room. The following instruments en-
able you to start / stop the engine and to
monitor its condition during operation.
B type
A Tachometer H Coolant high tempera-
ture alarm
B Hour meter I Lubricating oil low pres-
sure alarm
E Key switch J Water in sail drive seal
alarm
F Moisture cap for key
switch
K Battery low charge
alarm
G Stop button switch
SLOW
SLOW
min
min
-1
-1
Mpa
Mpa
trancasers
trancasers
OFF
OFF
ON
ON
ST ART
START
STOP
STOP
20
20
0
10
10
30
30
40
40
50
50
A
HI JK
BE F G
Instruments, equipment Functions
Key switch
Rotary switch with 4 posi-
tions
OFF
The switch key can be inserted or removed. All electric current is cut
off.
ON
The electric current to the controls and equipment is turned on.
Engine keeps running. To stop the engine, the key switch should be
in ON position. After stopping the engine, please turn OFF the key
switch.
START
The start position of the engine. The electric current to the starting
motor is turned on. When you release the key, it will automatically
turn to ON position.
GLOW
The start aid position of the engine. The electric current to the air
heater /glow plug is turned on. When you release the key, it will
automatically turn to ON position.
Note: When you don’t use the engine, please remove the key from the key switch and cover the
keyhole with the cap to protect from corrosion.
Stop button switch
Push button switch to stop the engine. The electric current to the stop solenoid
is turned on.
GLOW
OFF
ON
START