Technical data

OPERATION&MAINTENANCE MANUAL
reach about 80°C.
2, Increase or decrease of the diesel engine load and rotation speed shall be
carried out evenly and gradually. Under normal conditions, it is not allowed to add or
remove the load suddenly.
3. During the operation time of the diesel engine, pay attention often to seek if the
reading on the instruments on the instrument panel is normal. Pay attention to the
exhausted gas color and the operation sound. Stop the machine for inspection if
there is anything abnormal.
5Stopping
1. Before diesel engine stopping, it should reduce the load speed gradually to make
the speed at 900rpm around until the water temperature dropped to below 70 °
C, then it can be stopped by manipulation of the handle.
2. After diesel engine stops, it should rotate the ignition switch to the middle
Place.
3. In Winter, when the environmental temperature below 5 ° C, after stopping, open
the water switch on the body and radiator when temperature is below 60 ° C, give
out the cooling water to prevent frozen machine. There is no need of giving water
out if water has been added Ant freezing Fluid.
6、Security requirements
1. When engine works for generating-set, all the exposed parts and rotation parts
that may be danger to operators must device with a warning mark.
Protective Shell, partition steel should have sufficient rigidity, that only be removed
in the use of tools.
2. Diesel engine workplace must be well-ventilated, whenever
possible accumulation of flammable, toxic or asphyxiated gas in
place, should be installed ventilation facilities.
3. The Diesel Engine operation place must have non-slip cover.
Work channel, manipulation platforms, staircases and other
17