User Guide

26
TYROS Data List
Effect Parameter List / Liste der Effektparameter / Liste des paramètres d’effets
XG Effect Name Type MSB (Type LSB)
HALL1,HALL2 MSB = 01, LSB = 0, 1, 6, 7, 16-
ROOM1,ROOM2,ROOM3 MSB = 02, LSB = 0, 1, 2, 5, 6, 7, 16-
STAGE1,STAGE2 MSB = 03
PLATE (Reverb, Variation, Insertion block) MSB = 04, LSB = 0, 7, 16-
LARGE HALL, MEDIUM HALL MSB = 01, LSB = 2, 3
WARM ROOM, WOODY ROOM MSB = 02, LSB = 3, 4
RICH PLATE (Reverb block) MSB = 04, LSB = 1
DELAY L,C,R (Variation, Insertion block) MSB = 05
DELAY L,R (Variation, Insertion block) MSB = 06
ECHO (Variation, Insertion block) MSB = 07
CROSS DELAY (Variation, Insertion block) MSB = 08
EARLY REF1,EARLY REF2 (Variation, Insertion block) MSB = 09
GATE REVERB MSB = 10
REVERSE GATE (Variation, Insertion block) MSB = 11
WHITE ROOM MSB = 16
TUNNEL MSB = 17
CANYON MSB = 18
BASEMENT (Reverb, Variation, Insertion block) MSB = 19
KARAOKE1,2,3 (Variation, Insertion block) MSB = 20
TEMPO DELAY
TEMPO ECHO (Variation, Insertion block) MSB = 21
No. Parameter Display Value See Table Control
1 Reverb Time 0.3~30.0s 0-69 table#4
2 Diffusion 0~10 0-10
3 Initial Delay 0.1mS~99.3mS 0-63 table#5
4 HPF Cutoff Thru~8.0kHz 0-52 table#3
5 LPF Cutoff 1.0k~Thru 34-60 table#3
6
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11 Rev Delay 0.1mS~99.3mS 0-63 table#5
12 Density 0~4 0-4
13 Er/Rev Balance E63>R ~ E=R ~ E<R63 1-127
14 High Damp 0.1~1.0 1-10
15 Feedback Level -63~+63 1-127 table#16
16
No. Parameter Display Value See Table Control
1 Reverb Time 0.3~30.0s 0-69 table#4
2 Diffusion 0~10 0-10
3 Initial Delay 0.1mS~99.3mS 0-63 table#5
4 HPF Cutoff Thru~8.0kHz 0-52 table#3
5 LPF Cutoff 1.0k~Thru 34-60 table#3
6
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11
12
13
14 High Damp 0.1~1.0 1-10
15
16
No. Parameter Display Value See Table Control
1 Lch Delay 0.1~1638.3ms 1-16383
2 Rch Delay 0.1~1638.3ms 1-16383
3 Cch Delay 0.1~1638.3ms 1-16383
4 Feedback Delay 0.1~1638.3ms 1-16383
5 Feedback Level -63~+63 1-127 table#16
6 Cch Level 0~127 0-127 table#18
7 High Damp 0.1~1.0 1-10
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11
12
13 EQ Low Frequency 32Hz~2.0kHz 4-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15 EQ High Frequency 500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
No. Parameter Display Value See Table Control
1 Lch Delay 0.1~1638.3ms 1-16383
2 Rch Delay 0.1~1638.3ms 1-16383
3 Feedback Delay 1 0.1~1638.3ms 1-16383
4 Feedback Delay 2 0.1~1638.3ms 1-16383
5 Feedback Level -63~+63 1-127 table#16
6 High Damp 0.1~1.0 1-10
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11
12
13 EQ Low Frequency 32Hz~2.0kHz 4-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15 EQ High Frequency 500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
No. Parameter Display Value See Table Control
1 Lch Delay1 0.1~1486.0ms 1-14860
2 Lch Feedback Level -63~+63 1-127 table#16
3 Rch Delay1 0.1~1486.0ms 1-14860
4 Rch Feedback Level -63~+63 1-127 table#16
5 High Damp 0.1~1.0 1-10
6 Lch Delay2 0.1~1486.0ms 1-14860
7 Rch Delay2 0.1~1486.0ms 1-14860
8 Delay2 Level 0~127 0-127 table#18
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11
12
13 EQ Low Frequency 32Hz~2.0kHz 4-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15 EQ High Frequency 500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
No. Parameter Display Value See Table Control
1 L->R Delay 0.1~1486.0ms 1-14860
2 R->L Delay 0.1~1486.0ms 1-14860
3 Feedback Level -63~+63 1-127 table#16
4 Input Select L,R,L&R 0-2
5 High Damp 0.1~1.0 1-10
6
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11
12
13 EQ Low Frequency 32Hz~2.0kHz 4-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15 EQ High Frequency 500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
No. Parameter Display Value See Table Control
1 Type S-H, L-H, Rdm, Rvs, Plt, Spr 0-5
2 Room Size 0.1~7.0 0-44 table#6
3 Diffusion 0~10 0-10
4 Initial Delay 0.1mS~200.0mS 0-127 table#5
5 Feedback Level -63~+63 1-127 table#16
6 HPF Cutoff Thru~8.0kHz 0-52 table#3
7 LPF Cutoff 1.0k~Thru 34-60 table#3
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11 Liveness 0~10 0-10
12 Density 0~3 0-3
13 High Damp 0.1~1.0 1-10
14
15
16
No. Parameter Display Value See Table Control
1 Type TypeA,TypeB 0-1
2 Room Size 0.1~7.0 0-44 table#6
3 Diffusion 0~10 0-10
4 Initial Delay 0.1mS~200.0mS 0-127 table#5
5 Feedback Level -63~+63 1-127 table#16
6 HPF Cutoff Thru~8.0kHz 0-52 table#3
7 LPF Cutoff 1.0k~Thru 34-60 table#3
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11 Liveness 0~10 0-10
12 Density 0~3 0-3
13 High Damp 0.1~1.0 1-10
14
15
16
No. Parameter Display Value See Table Control
1 Reverb Time 0.3~30.0s 0-69 table#4
2 Diffusion 0~10 0-10
3 Initial Delay 0.1mS~99.3mS 0-63 table#5
4 HPF Cutoff Thru~8.0kHz 0-52 table#3
5 LPF Cutoff 1.0k~Thru 34-60 table#3
6 Width 0.5~10.2m 0-37 table#11
7 Heigt 0.5~20.2m 0-73 table#11
8 Depth 0.5~30.2m 0-104 table#11
9 Wall Vary 0~30 0-30
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11 Rev Delay 0.1mS~99.3mS 0-63 table#5
12 Density 0~4 0-4
13 Er/Rev Balance E63>R ~ E=R ~ E<R63 1-127
14 High Damp 0.1~1.0 1-10
15 Feedback Level -63~+63 1-127 table#16
16
No. Parameter Display Value See Table Control
1 Delay Time 0.1mS~400.0mS 0-127 table#7
2 Feedback Level -63~+63 1-127 table#16
3 HPF Cutoff Thru~8.0kHz 0-52 table#3
4 LPF Cutoff 1.0k~Thru 34-60 table#3
5
6
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127 table#15
●
11 Density 0~3 0-3
12
13
14
15
16
No. Parameter Display Value See Table Control
1 Delay Time 64th/3 ~ 4thx6 0-19 table#14
2 Feedback Level -63 ~ +63 1-127 table#16
3 Feedback High Dump 0.1 ~ 1.0 1-10
4 L/R Diffusion 1(-63ms) ~ 64(0ms) ~ 127(63ms) 1-127
5 Lag 1(-63ms) ~ 64(0ms) ~ 127(63ms) 1-127
6
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W=63 1-127 table#15
●
11
12
13 EQ Low Frequency 32Hz ~ 2.0kHz 4-40 table#3
14 EQ Low Gain -12 ~ +12dB 52-76
15 EQ High Frequency 500Hz ~ 16.0kHz 28-58 table#3
16 EQ High Gain -12 ~ +12dB 52-76
Parameters marked with a
●
in the “Control” column can be controlled from an AC1 (assignable cotroller1), etc. However, these only affect insertion type effects.