SWP2(config)#errdisable auto-recovery bpduguard interval 600
Disable automatic recovery after loop detection has caused the errdisable state.
SWP2(config)#no errdisable auto-recovery loop-detect
5.5.2 Show error detection function information
[Syntax]
show errdisable
[Input mode]
unprivileged EXEC mode, priviledged EXEC mode
[Description]
Shows information for the error detection function.
The following items are shown.
Whether automatic recovery from the errdisable state is enabled or disabled
The interface that is in the errdisable state, and the function that detected the error
[Example]
Show information for the error detection function.
SWP2>show errdisable
function auto recovery interval
-----------------------------------------------
BPDU guard disable
Loop detect enable 300
Port-security disable
port reason
----------------------------
port1.1 BPDU guard
port1.7 Loop detect
Command Reference | Interface control | 171