User Manual

[Keyword]
interface : Specify the monitor port to show
[Parameter]
ifname : Interface name of the LAN/SFP port
Monitor port to show
[Input mode]
unprivileged EXEC mode, priviledged EXEC mode
[Description]
Shows the port mirroring setting. If interface is omitted, the settings for all monitor ports are shown.
The following items are shown for each monitor port.
Item Description
Mirror Test Port Name Interface name of the mirror port
Mirror option Whether port mirroring is enabled or disabled
Mirror direction Direction of traffic that is mirrored
Monitored Port Name Interface name of the monitor port
[Example]
Show the mirroring port settings.
SWP1#show mirror
Mirror Test Port Name: ge1
Mirror option: Enabled
Mirror direction: both
Monitored Port Name: ge3
Mirror Test Port Name: ge1
Mirror option: Enabled
Mirror direction: receive
Monitored Port Name: ge4
Mirror Test Port Name: ge1
Mirror option: Enabled
Mirror direction: both
Monitored Port Name: ge5
10.1.11 Show interface status
[Syntax]
show interface [ifname]
[Parameter]
ifname : Interface name
Interface to show
[Input mode]
unprivileged EXEC mode, priviledged EXEC mode
[Description]
Shows the status of the interface specified by ifname. If ifname is omitted, shows the status of all interfaces.
The following items are shown.
Item Description
Interface Interface name
Link is
Link status *2 (if shutdown, shows the
cause)
If shutdown is specified : (by
shutdown)
Command Reference | LAN/SFP port control | 91