User Manual
Chapter 3
Configuration
3.1 Managing settings
The SWP1 uses the following configurations to manage its settings.
Types of configuration Description
User operations that can be
performed
Running configuration (running-config)
Setting values currently used for
operation. Managed in RAM.
Note
Save to startup configuration (in USER
mode)
Save some functions to backup
configuration (in DANTE mode)
Startup configuration (startup-config)
In USER mode, setting values saved in
ROM.
In DANTE mode, the same setting
values as the default configuration.
Note
Update by running configuration (in
USER mode)
Backup configuration (backup-config)
Setting values for some functions saved
in DANTE mode. Managed in ROM.
Update by running configuration (in
DANTE mode)
Default configuration (default-config)
Default setting values. Managed in
ROM.
Created based on the VLAN preset that
is selected by the settings of DIP
switches #2/#3 at start-up.
No operations possible
The start-up flow for the SWP1 system is as follows.
1. Reference DIP switch #1 and determine the CONFIG mode
• If DIP switch #1 is up (OFF), start up in DANTE mode
•
If DIP switch #1 is down (ON), start up in USER mode
2. Determine the startup configuration for each CONFIG mode
• For DANTE mode
• Use the default configuration that was selected according to the settings of DIP switches #2/#3
• For USER mode
• If a startup configuration for USER mode exists, use the corresponding data
• If a startup configuration for USER mode does not exist, use the default configuration that was selected according to
the settings of DIP switches #2/#3.
3. Load the startup configuration into RAM as the running configuration
• If a backup configuration exists in DANTE mode, overwrite the corresponding data onto the running configuration
If commands etc. are used to modify the settings while the SWP1 is running, the modified settings are immediately reflected in
the running configuration.
After modifying the running configuration, executing the write or copy command in USER mode will update the startup
configuration.
In DANTE mode, executing the backup-config command will update the backup configuration.
If you restart without saving the content that was specified or modified, the settings or modifications are lost. Please be aware of
this.
3.2 Default setting values
On the SWP1, the VLAN preset specified by DIP switches #2/#3 will be the default setting values. The VLAN preset types for
DIP switch #2/#3 settings are as follows.
• DIP switch #2/#3 settings
Setting position
VLAN preset type
#2 #3
Up (OFF) Up (OFF)
Normal
20 | Command Reference | Configuration