User`s manual
10
CHAPTER2 DeviceNet Unit
2-3 DeviceNet cable connections
Wire the DeviceNet cable to the accessory DeviceNet plug. Make the wiring connec-
tions by referring to the drawing below or the marks on the plug. Make sure the connec-
tions are correct! When finished wiring the cable to the plug, connect it to the DeviceNet
connector as shown below.
Fig. 2-1 DeviceNet cable wiring
*The 3 pins (shield) on the DeviceNet connector are not wired but this causes no prob-
lems during operation. These pins can be used if the customer wants a more secure
ground connection.
!
CAUTION
Always cut off the power before making the above connections.
Clamp the cable in place so it will not come loose.
Be sure to put an excessive pulling or weight load on the cable when wiring or
installing.
There are limits on the total cable length and the cable length between stations so
always consult the instruction manual for the master station sequencer (PLC).
MEMO
MEMO
Set MAC ID and communication speed before connecting the DeviceNet cables.
(See "2-5-2 Setting MAC ID and communication speed".)
DeviceNet connector
DeviceNet cable
Controller
1. V- (black)
2. CAN_L (blue)
3. Shield
4. CAN_H (white)
5. V+ (red)
1 2 3 45
DeviceNet plug
MSTB2, 5/5-STF-5, 08AUM
Phoenix Contact