Specifications

APPLICATION
Compact
single-axis robots
TRANSERVO
Single-axis robots
FLIP-X
Linear motor
single-axis robots
PHASER
Cartesian
robots
XY-X
SCARA
robots
YK-XG
Pick & place
robots
YP-X CLEAN
CONTROLLER
INFORMATION
420
Robot
positioner
Pulse string
driver
Robot
controller iVY
Option
Electric
gripper
ERCD
Input / output wiring diagram
ROB
PB
RS232C
communication
control
I/O. CN
Sequence input
I/O. CN
Sequence output
EXT. CN
DC24V
I/O. CN
pulse output
SG
Power terminal base
DC24V
3A to 4.5A
(Variable depending
on robots)
+
-
ABS-PT
INC-PT
AUTO-R
STEP-R
ORG-S
RESET
SERVO
LOCK
DI0
DI1
DI2
DI3
DI4
DI5
(SVCE)
A1
B1
A2
B2
A3
B3
A4
B4
A5
B5
A6
B6
A7
B7
A8
DO0
DO1
DO2
DO3
DO4
DO5
END
BUSY
READY
FG
A9
B9
A10
B10
A11
B8
B11
A12
B12
A13
EMG1
EMG2
24V
24G
1
2
3
4
A17
B17
A18
B18
A19
B19
B14
B13
PA+
PA-
PB+
PB-
PZ+
PZ-
GND
FG
24P
24N
FG
Pulse train input / output wiring diagram
ROB
PB
I/O. CN
pulse input
I/O. CN
Sequence input
I/O. CN
Sequence output
EXT. CN
DC24V
I/O. CN
pulse output
SG
SG
Power terminal base
DC24V
3A to 4.5A
(Variable depending
on robots)
+
-
A15
B15
A16
B16
A14
PCLR
ORG-S
RESET
SERVO
INH
DI0
DI1
DI2
DI3
DI4
DI5
B2
A3
B3
A4
B4
A5
B5
A6
B6
A7
B7
DO0
DO1
DO2
DO3
DO4
DO5
IN-POS
SRDY
ALM
FG
A9
B9
A10
B10
A11
B8
B11
A12
B12
A13
EMG1
EMG2
24V
24G
1
2
3
4
PULS+
PULS-
DIR+
DIR-
GND
A17
B17
A18
B18
A19
B19
B14
B13
PA+
PA-
PB+
PB-
PZ+
PZ-
GND
FG
24P
24N
FG
Robot Language Table
Command Description
MOVA Moves to a point data position.
MOVI Moves from current position by amount of point data.
MOVF Moves until a specied DI input is received.
JMP Jumps to a specied label in the specied program.
JMPF
Jumps to a specied label in a specied program
according to the input condition.
JMPB
Jumps to a specied label when general-purpose
input or memory input is in the specied state.
L
Denes the jump destination for a JMP or JMPF
statement, etc.
CALL Runs another program.
DO
Turns general-purpose output or memory output on
or off.
WAIT
Waits until general-purpose input or memory input is
in the specied state.
TIMR
Waits the specied amount of time before advancing
to the next step.
P Denes point variable.
P+ Adds 1 to point variable.
P- Subtracts 1 from point variable.
SRVO Turns servo on or off.
STOP Temporarily stops program execution.
ORGN Performs return-to-origin.
TON Runs a specied task.
TOFF Stops a specied task.
JMPP
Jumps to a specied label when the axis position
condition meets the specied conditions.
MAT Denes a matrix.
MSEL Species a matrix to move.
MOVM Moves to a specied pallet work position on matrix.
JMPC
Jumps to a specied label when the counter array
variable C equals the specied value.
JMPD
Jumps to a specied label when the counter variable
D equals the specied value.
CSEL Species an array element for counter array variable C.
C Denes counter array variable C.
C+ Adds a specied value to counter array variable C.
C-
Subtracts a specied value from counter array
variable C.
D Denes counter variable D.
D+ Adds a specied value to counter variable D.
D- Subtracts a specied value from counter variable D.
SHFT
Shifts the coordinate position by amount of specied
point data.
IN
Stores bit information on specied general-purpose
input or memory input into counter variable D.
OUT
Outputs the value of counter variable D to specied
generalpurpose output or memory output.
LET
Assigns the value of a specied variable to another
variable.
TORQ Denes the maximum torque command value.