User`s manual
13
CHAPTER2 CC-Link Unit
2-5 Controller system settings (remote station)
The communication speed and station No. must be set so that the controller can be cor-
rectly identified as a remote station on the CC-Link system.
Thy are set from the HPB.
These settings are enabled after the controller is restarted.
2-5-1 Validating the CC-Link unit
Before the CC-Link unit can be used, it must first be set as follows, to allow it to be
identified by the controller.
1) Press
F3
(SYS) on the initial screen.
2) Press
F4
(next) to switch to the func-
tion display and then press
F2
(OPT).
3) Press
F1
(DEV).
4) The current CC-Link unit identity status
appears on the display.
Now, using the number key pad, enter a 1
to make the CC-Link unit identifiable
from the controller or enter a 0 to prevent
it being identified from the controller, and
then press the
key.
5) When entry is finished, the screen returns
to 4).
[MENU]
select menu
1EDIT2OPRT3SYS 4MON
[SYS]
select menu
1SAFE2OPT 3UTL 4next
[SYS-OPT]
select menu
1DEV 2NODE3SPD 4next
[SYS-OPT-DEV]
CC-Link=
0
0:invalid 1:valid
[SYS-OPT-DEV]
CC-Link=
1
0:invalid 1:valid